PDA User Manual

Ikôn Rugged PDA (Windows CE 5.0) User Manual 175
Chapter 5: Configuration
Decoded (Internal) Scanners
Code 93
are successfully decoded within one laser scan. This option should be enabled when bar
codes are in proximity to each other.
2D UPC Half Block Stitching
Setting this parameter to on enables “UPC Half Block Stitching” for the omnidirectional
scanner engine only.
5.14.2.12 Code 93
Enabled
Set this parameter to on to enable “Code 93”, or OFF to disable it.
Set Length L1 And Set Length L2
Lengths for “Code 93” can be set for Any length, Length within a range, One discrete length
or Two discrete lengths. The length of a code refers to the number of characters (i.e., human
readable characters), including check digit(s).
Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where
you can define the code length that will be recognized by your scanner.
Choosing One discrete length allows you to decode only those codes containing a selected
length. Choosing Two discrete lengths allows you to decode only those codes containing two
selected lengths. Length within a range allows you to decode a code type within a specified
range from 4 to 55.
Field Size/Chars
Refer to page 170 for details.
5.14.2.13 Codabar
Enabled
Set this parameter to on to enable “Codabar”.
Set Length L1 And Set Length L2
Lengths for “Codabar” can be set for Any length, Length within a range, One discrete
length, or Two discrete lengths. The length of a code refers to the number of characters
(i.e., human readable characters), including check digit(s).
Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where
you can define the code length that will be recognized by your scanner.