Owner`s manual

TROUBLE SHOOTING
SYMPTOM
A:
NO
AC
POWER OUTPUT,
THE
RED
LED
LIGHTS.
POSSIBLE CAUSES SUGGESTION
The
connected
AC
products are rated
at
more
than
150
Watts
Use
the product with a total
power
rating
(PNVR300) , 220 Watts (PNVR450) or 400 Watts
(PNVRBOO),
less
than
t50
Watts
(PNVR300),
220
Watts
the
overload shutdown occurred.
(PNVR450)
and
400
Watts
(PNVRBOO).
The
connected
AC
products are rated
at
less
than
150 Watts
Use
the
product
not
exceeds
the
inverter's
(PNVR300) , 220 Watts (PNVR450) or 400 Watts
(PNVRBOO),
surge
capacity,
300
Watts
(PNVR300)
,
450
the
high starting surge causes
the
overload shutdown.
Watts
(PNVR450)
and
BOO
Watts
(PNVRBOO).
The
battery is discharged (alarm sounds) Recharge battery.
The inverter overheated
Tum
011
the inverter
and
allow to
cool
for
15
minutae.
Clear
blocked
fan
(pNVR300
IPNVR45OJPNVRBOO)
or
re"""",
the
objects
COYSring
the
ventilation.
SYMPTOM
B:
NO
AC
POWER OUTPUT,
NO
LED
LIGHTS
ARE
ON.
POSSIBLE CAUSES SUGGESTION
The lighter socket or
12
Volt
outlet has been poor contacted Press plug into socket firmly.
The
lighter socket
or
12 Volt may require ignition
to
be on.
Turn
key to accessory position.
The
fuse
of
cigarette lighter
or
12 Volt
outlet
is blown
Check
vehicle fuses
and
replace.
The
fuse
of
inverter is blown Check to make sure the inverter
is
connected to a power source with correct
voltage and polarity.
Replace fuse.
The inverter has been connected with reverse
DC
input The inverter needs repjairment
polarity. if the probable damage has occurred.
6