Pyramid Universal Dome Interface Installation Manual Please read this manual before operating the Pyramid system
Pyramid Universal Dome Interface Installation Manual IMPORTANT The first few pages of these instructions contain important information on safety and product conformity. Please read, and ensure that you understand this information before continuing.
Installation Manual Pyramid Universal Dome Interface CONTENTS Product Safety ...................................................................................................................................................................................... 4 Electromagnetic Compatibility (EMC) ............................................................................................................................................. 4 Manufacturers Declaration of Conformance ..........................
Pyramid Universal Dome Interface Installation Manual PRODUCT SAFETY WARNING Please follow these instructions as you install the equipment and keep them for future use. Installation is only to be carried out by competent, qualified and experienced personnel in accordance with the country of installations National Wiring Regulations. Failure to do so can result in injury or death by electric shock.
Installation Manual Pyramid Universal Dome Interface THE UNIVERSAL DOME INTERFACE The Pyramid Universal Dome Interface (UDI) enables a range of dome products to be connected and controlled via the Pyramid network with a minimum of effort. The UDI can be configured to operate in a number of different dome protocols, and because of this it can translate commands from the Pyramid network to the correct format for the specific product.
Pyramid Universal Dome Interface Installation Manual CONNECTING AND CONFIGURING THE UDI The two end panels of the Universal Dome Interface contain all the connectors and switches that are required to connect and configure the device. The panels also contain a number of receive and transmit LEDs which enable easy system diagnosis, and a service pin that is used when the UDI is addressed.
Installation Manual Pyramid Universal Dome Interface CONNECTING AND CONFIGURING THE UDI Dip switch number 6 is used to enable or disable the auto-iris function. If the auto-iris functionality is enabled (dip switch 6 UP), the iris level on the connected device will be readjusted for the lighting conditions every thirty seconds. If this functionality is disabled (dip switch 6 DOWN), iris adjustments will have to be made manually using a system keyboard.
Pyramid Universal Dome Interface Installation Manual CONNECTING AND CONFIGURING THE UDI Pyramid Data Connector - This three-way terminal is used to connect the UDI to the Pyramid network. This can be either a RS485 or FTT10 network depending on the UDI variant in use. Connect the UDI to the network using pins 2 and 3 (labelled + and - to indicate polarity), and connect the cable screen to ground on pin 1 (labelled ).
Installation Manual Pyramid Universal Dome Interface CONNECTING AN ULTRAK DOME CAMERA 3. On the dome camera itself there is a PCB which includes three rotary switches. These rotary switches are labelled S1, S2 and S3, and they should be used to set the dome address to 1. To do this, set the first rotary switch (S3) to 0, the second rotary switch (S2) to 0 and the third rotary switch (S1) to 1, as shown below: White indicates switch position S4 S3 S2 S1 Configuring an Ultrak Dome 4.
Pyramid Universal Dome Interface Installation Manual CONNECTING A VICON DOME CAMERA To connect a Vicon dome camera to the UDI, follow the steps below: CAUTION When connecting the UDI to a dome, reference should also be made to documentation provided with the dome. 1. Connect the five-way terminal block on the top of the Vicon dome camera to the wire from the UDIs Dome Data Connector. Use the diagram below as a guide: Connecting a Vicon Dome to the UDI 2.
Installation Manual Pyramid Universal Dome Interface CONNECTING A MARK MERCER DOME CAMERA To connect a Mark Mercer dome camera to the UDI, follow the steps below: CAUTION When connecting the UDI to a dome, reference should also be made to documentation provided with the dome. 1. Remove the top panel from the dome camera housing. The connections are made inside this top panel. 2. Inside the top panel, locate the twelve-way terminal block to which power, video, alarm and network connections are made.
Pyramid Universal Dome Interface Installation Manual CONNECTING A JVC DOME CAMERA 3. Locate the rotary address switches and the settings dip switch panel on the dome camera. On the TK-C675, they are located on the side of the dome camera, while on the TK-C676, they are located on the underside of the top panel. 4. Using the two rotary switches, set the dome address to 1. To do this, set the right rotary switch to 1, and the left rotary switch to 0 as shown in the diagram below: Configuring an JVC Dome 5.
Installation Manual Pyramid Universal Dome Interface CONNECTING A DENNARD DOME CAMERA Dennard dome cameras are supplied with a flying lead connector which is connected to the socket on the top of the dome housing. The flying lead connector is a multicore cable, and two of the wires are used specifically for network connections. To connect these wires to the UDI, follow the steps below: CAUTION When connecting the UDI to a dome, reference should also be made to documentation provided with the dome. 1.
Pyramid Universal Dome Interface Installation Manual CONNECTING AN AD/SENSORMATIC DOME CAMERA To connect a Sensormatic dome camera to the UDI, follow the steps below: CAUTION When connecting the UDI to a dome, reference should also be made to documentation provided with the dome. 1. Remove the dome assembly from the base. The dome can be connected to the UDI in one of two ways.
Installation Manual Pyramid Universal Dome Interface CONNECTING A VISTA DOME CAMERA To connect a Vista dome camera to the UDI, follow the steps below: CAUTION When connecting the UDI to a dome, reference should also be made to documentation provided with the dome. 1. Remove the dome from the mounting bracket to expose the connectors. 2. Connect the wire from the UDIs Dome Data Connector, using the diagram below as a guide: Connecting a Vista PowerDome to the UDI 3.
Pyramid Universal Dome Interface Installation Manual ADDRESSING A UDI WITH THE PYRAMID 1 KEYBOARD A UDI can also be addressed using the Pyramid 1 Keyboard. Follow the steps below: 1. Connect up a Pyramid Mk1 Keyboard to the UDI. This can be done directly by connecting the network card on the keyboard to the Pyramid Data Connection on the UDI, or remotely through the Pyramid network in the normal way. 2. Using the keyboard, insert the Installers Card and log on with the PIN number 1892. 3.
Installation Manual Pyramid Universal Dome Interface ADDRESSING A UDI WITH THE PYRAMID 2 KEYBOARD 7. Press the Receiver Address soft-key. The keyboard LCD displays a message asking the operator to press the service pin. 7 12... 12... 6 Operator Rx Utilities Operator Rx Utilities 5 Addressing a UDI 8. So that the keyboard can identify the UDI, press its service pin. On the UDI, the service pin is a small button inside an access hole. Use a small screwdriver to press the service pin.
Pyramid Universal Dome Interface Installation Manual DOME OPERATIONS AVAILABLE WITH THE PYRAMID 2 KEYBOARD Baxall ProDome The UDI enables the user to use the dome cameras menu system (when installed). To enter the dome camera menu system use the keyboard to: 1. Select a monitor on which to view the menus by pressing the monitor number (soft-keys 1 to 9) followed by the monitor soft-key. 2. Select a dome camera by pressing the camera number (soft-keys 1 to 9) followed by the camera soft-key. 3.
Installation Manual Pyramid Universal Dome Interface DOME OPERATIONS AVAILABLE WITH THE PYRAMID 2 KEYBOARD When in Menu mode on a Panasonic dome camera, it is possible to enter the Special menu by pressing the Iris Close key. After programming a preset on a Dennard Dome camera, press the Iris Open key to re-enable PTZ fuctionality. On a JVC Dome camera, if the menu is exited by using the joystick, PTZ functionality will freeze.
Page 20 See note See note Toggle Colour/IR mode 123 Access/Exit Main Menu Access/Exit Main Menu O Dome PTZ Operation Quick-Reference Table Access/Exit Main Menu 180 Flip Digital Zoom On/Off Access Menu 3 Access Menu 2 Auto U-Turn On/Off Access Menu 4 O 180 Flip Access/Exit Main Menu Program Tour Start/Stop O 180 Flip Program Pattern Note: See Dome vendor’s specification for preset availability (maximum 100 presets). Some dome variants may not support all features listed.
Menu delete Numeric 1-9 (can also be used to select menu items by their numeric line) Numeric 0 Alpha A-Z (see ascii chart) Alpha a-z (see ascii chart) PRESETS 1-9 PRESET 10 PRESET 65-90 PRESET 97-122 Menu privacy ‘Select’ key FOCUS NEAR IRIS CLOSE Escape (i.e., move back one menu) Cycle field options ZOOM OUT Menu save Enter (i.e., confirm change to menu value) Enter (i.e., confirm change to menu value) Enter (i.e.
Pyramid Universal Dome Interface Installation Manual Character Preset Number Character Preset Number A 65 a 97 B 66 b 98 C 67 c 99 D 68 d 100 E 69 e 101 F 70 f 102 G 71 g 103 H 72 h 104 I 73 i 105 J 74 j 106 K 75 k 107 L 76 l 108 M 77 m 109 N 78 n 110 O 79 o 111 P 80 p 112 Q 81 q 113 R 82 r 114 S 83 s 115 T 84 t 116 U 85 u 117 V 86 v 118 W 87 w 119 X 88 x 120 Y 89 y 121 Z 90 z 122 32 Ascii
Installation Manual Pyramid Universal Dome Interface SPECIFICATIONS Physical Size: Weight: 130mm (L) x 115mm (W) x 37 mm (H) 265g Colour: Black Temperature: 0O to 50OC Power Consumption: 12V DC or 24V AC drawing a maximumof 150mA Usage Enables a range of dome products to be connected and controlled via the Pyramid network with a minimum of effort.
Baxall Limited, Stockport, England. Visit our Web site: http://www.baxall.com Baxall Limited reserve the right to make changes to the product and specification of the product without prior notice to the customer.