CHAPTER 4: POWERING UP & KEYPAD OPERATIONS 
Before using the system, all items connected to the RS-485 communications bus must be allocated 
a unique address. 
4.1 Default Codes 
User: 1234. Master Manager: 2222 Engineers: 1111 
4.2 Initial Power Up 
Power up the PCX system on mains only, an alarm will be generated. Proceed to the nearest 
keypad, which will display (from power up): 
¾ The following will be displayed: 
After 10 seconds, the display will blank, and 
then show ‘Address’. Enter 00 and then press 
the key 
(Press the  key for further options just as 
tag volume, keypad brightness etc). 
Press the key to exit the addressing 
function, and enter 1234 (default master code) 
to silence an alarms that occur. 
When the display shows: ‘Battery Fault’ and 
NOT before, connect the battery to the panel. 
In the keypad function there are also other individual options such as: language, the status of the 
keypad inputs, key-click volume, tag volume, master volume and the tag ID. 
The tag ID is used to show the identification code for each proximity tag. 
To enter this keypad function at any time, please follow the instructions below. 
4.3 Notes on Addressing Keypads 
To address further keypads on the EURO system, press and hold the key until “KEYPAD 
CODE” is displayed. Then enter ‘2000’ as the code. This will take you to the screens above. Once 
this has been done you will need to assign the keypad in engineers mode, see ‘Assign 
Keypads/Readers’ on page: 24. Note: To address the readers you must select the relevant 
switches on the circuit board, see the installation manual for more information. 
Any keypad that is not properly assigned will have a blank display until they are addressed. 