4.8 Forced Arm On Inputs 
The ‘Forced Arm On Inputs’ allows the Engineer to arm / disarm the system using the Engineer 
Code, forcing it to arm despite inputs in fault condition, and nominate which inputs must be 
triggered to generate an alarm condition. This is a useful feature if you need to test a system in a 
building where people are walking around. 
NOTE 1: The system will give the correct DigiCom response to the arming, and any 
resulting alarm. On disarming the system (With the Engineer code or the User code), the system 
will revert to normal mode. 
NOTE 2: If the system has been armed by any other code, the Engineer code will not disarm 
it. 
Visual Keypad Programming Procedure 
FORCED ARM ON INPUT 
¾ Enter the Engineer Code (default 9999). 
¾ Any active faults will be displayed, press the 
 key. 
¾ Press the key again. 
¾ ‘FORCED ARM ON INPUT’ will be displayed 
¾ Select the first input to be forced armed and 
press the key. 
¾ Select the second input to be forced armed 
and press the key. 
Select the partition(s) / level arm you would like 
to arm. Press the key. The system then will 
begin to arm. 
When the input is triggered (or open and closed 
again) the alarm will be activated. 
Please note the primary partitions are A,B,C 
and D. 