Installation manual
PCX 256 PROGRAMMING MANUAL                                                                  
Page: 50    RINS868-6 
Visual Keypad Programming Procedure 
REVIEW LOGS 
Review Logs 
Using the and keys, scroll to ‘REVIEW 
LOGS?’ Press the key 
Panel Log 
Press the key to view the panel log. 
You will be returned to the Engineer Menu. 
The log will be displayed. Use the and 
Gkeys to scroll through the log. For more 
information on an event (such as alarm silenced 
for example) press the F key. 
When you wish to exit, press the key. 
Access Log 
Repeat the above for the Access log. When you 
wish to exit, press the key. You will be 
returned to the Engineer Menu. 
5.20 Engineer Tests 
The Engineer Tests function allows the engineer to test inputs, PGM’s, batteries and the bell. 
5.20.1 Sounds To Play 
This function allows you to listen to the different tones the PCX system makes so you can 
recognise them. They have a choice of: Chime, Chime Follow, Exit, Exit Fault, Entry, Tech Fault, 
Tamper, Alarm, PA, and Fire. (The default is No Sound) 
5.20.2 Walk Test 
Please note that the walk test feature can only be used when engineer’s mode is exited after the 
programming of inputs
. 
This function allows the engineer to test all programmed inputs on the system. The inputs that 
haven’t been activated will be shown on the display. Once all the inputs have been walk tested, 
‘Walk Test Completed’ will be displayed. 
When walk-testing a double-knock detector, it must be triggered twice within the preset period. 
When testing dual-trip detectors you must first open detector one and then trigger the second 
detector; next open the second detector and trigger the first detector. 