Cut Sheet
UL 1703; VDE Quality Tested; CE-compliant;
IEC 61215:2016; IEC 61730:2016, Application class A
Specications subject to technical changes © Hanwha Q CELLS Q.PEAK DUO BLK-G5_300-320_2018-03_Rev02_NA
At least 98 % of nominal power during rst year.
Thereafter max. 0.54 % degradation per year.
At least 93.1 % of nominal power up to 10years.
At least 85 % of nominal power up to 25years.
All data within measurement tolerances.
Full warranties in accordance with the warranty
terms of the Q CELLS sales organization of your
respective country.
Typical module performance under low irradiance conditions in
comparison to STC conditions (25 °C, 1000 W/m
2
).
Hanwha Q CELLS America Inc.
300 Spectrum Center Drive, Suite 1250, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL inquiry@us.q-cells.com | WEB www.q-cells.us
MECHANICAL SPECIFICATION
Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE
IRRADIANCE [W/m²]
RELATIVE EFFICIENCY [%]
200 400 600 800 1000
110
100
90
80
Irradiance [W/m²]
Relative efficiency [%]
Format 66.3 in × 39.4 in × 1.26 in (including frame)
(1685 mm × 1000 mm × 32 mm)
Weight 41.2 lbs (18.7 kg)
Front Cover 0.13 in (3.2 mm) thermally pre-stressed glass with anti-reflection technology
Back Cover Composite film
Frame Black anodized aluminum
Cell 6 × 20 monocrystalline Q.ANTUM solar half-cells
Junction box 2.76-3.35 in × 1.97-2.76 in × 0.51-0.83 in
(70-85 mm × 50-70 mm × 13-21 mm), decentralized, IP67
Cable 4 mm² Solar cable; (+) ≥ 43.3 in (1100 mm), (−) ≥ 43.3 in (1100 mm)
Connector Multi-Contact MC4, IP68
PROPERTIES FOR SYSTEM DESIGN
Maximum System Voltage V
SYS
[V]
1000 (IEC) / 1000 (UL)
Safety Class II
Maximum Series Fuse Rating [A DC] 20 Fire Rating
C
(IEC) / TYPE 1 (UL)
Max. Design Load, Push / Pull (UL)
2
[lbs/ft
2
] 75 (3600 Pa) / 55 (2667 Pa) Permitted module temperature
on continuous duty
− 40 °F up to +185 °F
(− 40 °C up to +85 °C)
Max. Test Load, Push / Pull (UL)
2
[lbs/ft
2
] 113 (5400 Pa) / 84 (4000 Pa)
2
see installation manual
QUALIFICATIONS AND CERTIFICATES
PACKAGING INFORMATION
Number of Modules per Pallet 32
Number of Pallets per 53' Trailer 30
Number of Pallets per 40' High Cube Container 26
Pallet Dimensions (L × W × H) 69.3 in × 45.3 in × 46.9 in
(1760 mm × 1150 mm × 1190 mm)
Pallet Weight 1415 lbs (642 kg)
NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use
of this product.
EN
RELATIVE EFFICIENCY
COMPARED TO NOMINAL POWER [%]
100
95
90
85
80
75
155 25200 10
YEARS
98
Q CELLS
Industry standard for tiered warranties
*
Industry standard for linear warranties
*
*
Standard terms of guarantee for the 10 PV companies
with the highest production capacity in 2014 (as at: September 2014)
NA
DETAIL A
0.630" (16mm)
0.335" (8.5mm)
0.965" (24.5mm)
38.58" (980mm)
66.3" (1685mm)
4 × Mounting slots (DETAIL A)
Frame
39.4" (1000mm)
37.44" (951mm)
1.26" (32mm)
8 × Drainage holes
13.9“ (352.5mm)
4 × Grounding points ø 0.177" (4,5mm)
≥ 43.3“ (≥ 1100 mm)
≥ 43.3“ (≥ 1100 mm)
Certified
UL 1703
(254141)
TEMPERATURE COEFFICIENTS
Temperature Coefficient of I
SC
α
[% / K] + 0.04 Temperature Coefficient of V
OC
β
[% / K] − 0.28
Temperature Coefficient of P
MPP
γ
[% / K] − 0.37 Normal Operating Module Temperature NMOT [°F] 109 ± 5.4 (43 ± 3 °C)
ELECTRICAL CHARACTERISTICS
POWER CLASS 300 305 310 315 320
MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC
1
(POWER TOLERANCE +5 W / −0 W)
Minimum
Power at MPP
1
P
MPP
[W] 300 305 310 315 320
Short Circuit Current
1
I
SC
[A] 9.72 9.78 9.83 9.89 9.94
Open Circuit Voltage
1
V
OC
[V] 39.48 39.75 40.02 40.29 40.56
Current at MPP I
MPP
[A] 9.25 9.31 9.36 9.41 9.47
Voltage at MPP V
MPP
[V] 32.43 32.78 33.12 33.46 33.80
Efficiency
1
η
[%] ≥ 17.8 ≥ 18.1 ≥ 18.4 ≥ 18.7 ≥ 19.0
MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT
2
Minimum
Power at MPP P
MPP
[W] 224.1 227.8 231.6 235.3 239.1
Short Circuit Current I
SC
[A] 7.83 7.88 7.92 7.97 8.01
Open Circuit Voltage V
OC
[V] 37.15 37.40 37.66 37.91 38.17
Current at MPP I
MPP
[A] 7.28 7.32 7.37 7.41 7.45
Voltage at MPP V
MPP
[V] 30.78 31.11 31.44 31.76 32.08
1
Measurement tolerances P
MPP
± 3 %; I
SC;
V
OC
± 5 % at STC: 1000 W/m
2
, 25 ± 2 °C, AM 1.5 G according to IEC 60904-3 ∙
2
800 W/m², NMOT, spectrum AM 1.5 G