User's Manual

4–Non-Interactive Commands
Command Summary
SN0054614-00 K 4-37
-o
(Output to a File)
To output result and status messages into a file, type -o, followed by the file
name. For example, to save LUN information to a file named systemLUNinfo:
# scli -l -o systemLUNinfo
a
Connection Options:
0 = Loop only
1 = Point-to-point only
2 = Loop preferred, otherwise point-to-point
3 = Point-to-point preferred, otherwise loop (QLA22xx adapters only)
b
Data Rate (QLA23xx/QLA24xx/QLE23xx/QLE24xx and 8Gb adapters):
0 = 1 Gb
1 = 2Gbs
2 = Auto
3 = 4 Gbs
4 = 8 Gbs
c
EnableBIOS option not available on 4Gb adapter.
d
EnableExtendedLogging option not available on PPC64 or SPARC.
e
Operation mode (QLA/QLE23xx, QLA/QLE24xx, and 8Gb adapters):
0 = interrupt for every I/O completion
5 = interrupt when interrupt delay timer expires
6 = interrupt when interrupt delay timer expires or no active I/O
NOTE:
QLA200/210 adapters have a limited set of parameters that can be
changed.
NOTE:
ξ‚„ The -o option is valid only in non-interactive mode.
ξ‚„ This option can be used with all non-interactive mode options that have
a corresponding interactive mode option (see Table 4-1). The option
must be the first or last command in the command line.
ξ‚„ If the file already exists, new data are appended to the current file.