Release Notes Grass Valley Series 7000 Signal Management Systems Software Release 6.
Customer Support Tektronix Grass Valley Products is committed to providing the most responsive and professional product support available. We have a fully staffed, highly trained support team ready to respond to anything from a simple question to an emergency repair. Support is available via telephone or email. For new and updated customer support documents, as well as new product information, check the Tektronix web site and Grass Valley Product’s web page.
Contents SMS 7000 Release Notes Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Enhancements and Fixes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Enhancements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Fixes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents iv SMS 7000 Release Notes
Version 6.41 May 1998 SMS 7000 Release Notes Introduction This document contains release notes for Version 6.41 (170035-07) of the Series 7000 Signal Management System. This document describes the operational changes, the software, firmware, and hardware required, and the procedures for performing the update from Versions 3.x, 4.x, 5.x and 6.x systems to 6.41. Note Please read Software, Hardware, and Firmware Required on page 2 before proceeding with this Installation.
Version 6.41 Software, Hardware, and Firmware Required Releases previous to 6.x are composed of software, firmware, and hardware assemblies; however, versions 6.x and 6.41 are software upgrades only. ■ Software is on IBM PC compatible 1.44 MB 3.5 inch floppy diskettes ■ Firmware is loaded into ROMs and must be installed by replacing the appropriate ROM IC on an appropriate Series 7000 module ■ Required firmware/hardware changes to Version 3.x MCPU to install and run Version 6.
Software, Hardware, and Firmware Required No required firmware/hardware changes to Version 6.x MCPU to install and run Version 6.41. Version 6.x to 6.41 is a software upgrade only. ■ On page 14 is a matrix of the appropriate versions of hardware (circuit modules) for each Series 7000 Release. Note Whenever a circuit module or any part is updated to a new level, the dash version of the part must be re-marked to keep service records accurate.
Version 6.41 Upgrade Kit number 170183-01 is for 4.x to 6.41 upgrade. Table 2. Version 6.x Upgrade Kit for 4.x to 6.
Software, Hardware, and Firmware Required 6.41 MCPU Software Five 3.5 inch floppy diskettes contain the Series 7000 V6.41 software (GV part number 170035-08). Diskettes #1 & #2; MCPU, Node Controller, Amezi, Tally Manager, and Panel Application Software 6.41 has been pre-loaded into the 2MByte Flash Memory assemblies provided in the MCPU Upgrade Kits.
Version 6.41 Table 5. Diskettes 1 & 2 Contents - (continued) File Description MCO.MOT a Custom Machine Control Panel Application Software MCOLOAD.BAT PROGCP.RED Software Load Batch File for MCO.MOT only 7000 Sys. Diag. Script to Program Control Panels PROGNC.REDa 7000 Sys. Diag. Script to Program Node Controllers PXD.MOT a Programmable XY Destination Panel Application Software PXS.MOT a Programmable XY Source Panel Application Software R6.FTP FTP Script for option 1 (normal load) R6BIG.
Software, Hardware, and Firmware Required Diskette #3, Disk, PC GUI Application Software (P/N 151159-07 Load diskette #3 into an IBM compatible PC running Windows 3.1. Table 6. Diskette 3 Contents File Description SMS7000.EXE The GUI executable (P/N 151221-05) SETUP.EXE The GUI install program TKLIB.DLL PC NFS Dynamic Link Library README.GUI Installation Notes Diskette #4, Disk, Visual Status Display Software (P/N 153324-03) Load diskette #4 into an IBM compatible PC running Windows 3.1.
Version 6.41 Table 9. Release 6.41 Software Versions 8 Software/Firmware Version File MCPU Application sms SMS6.4 SMS MCPU Boot ROM SMSB5.30 Network ASN (Amezi) AMEZ6.3 AMEZI.BIN Network GSC CSOS6.3 CSOS.BIN Network GSC STMG6.3 STMG.BIN Network PSD LBCP6.3 (sms) Network RPC LBCP6.3 (sms) Network IPC -------- (sms) Network SDT LBCP6.3 (sms) NBX (Node Ctrlr) NBX_6.02 Node Controller App. 6.41 CPOS CPOS1.00 Panel App. BPS32 BPS6.4 BPS32.MOT Panel App. UCP UCP6.4 UCP.
Software, Hardware, and Firmware Required Software/Firmware Compatibility Matrix Table 10 below is a matrix of Series 7000 software releases beginning with the 5.30 release showing the various supported software and firmware. Information on releases prior to version 5.3 is shown in Table 11 on page 12. Table 10. Software Compatibility Matrix Versions 5.30 and Above Software/Firmware Assembly Part Number Disk, MCPU Application Software 5.30 151157-07 Disk, MCPU Application Disk 1 Software 5.
Version 6.41 Table 10. Software Compatibility Matrix Versions 5.30 and Above - (continued) Software/Firmware Assembly 10 Part Number Firmware, HX NC App Odd R5.30 151108-05 Firmware, Node Cntrl R3 Boot ROM (U18) 052865-03 Firmware, Node Cntrl R3 Boot ROM (U17) 052866-03 Firmware, Tally Module 151036-01 Firmware, FCX Frm Ctrlr Up Ver 3.0 052854-02 Firmware, NBX Comm Proc Up R4.0 052855-03 Firmware, NBX Comm Proc Up R6.0 052855-04 Software, Amezi Driver 5.30 none Software, Amezi Driver 5.
Software, Hardware, and Firmware Required Table 10. Software Compatibility Matrix Versions 5.30 and Above - (continued) Software/Firmware Assembly Part Number Software, Node Ctrl Appl 6.3 none Software, Node Ctrl Appl 6.4 none Software, Node Ctrl Appl 6.41 none Software, PC GUI & Support Appl 5.30 none Software, PC GUI & Support Appl 5.41 none Software, PC GUI & Support Appl 6.0 none Software, PC GUI & Support Appl 6.3 none Software, PC GUI & Support Appl 6.
Version 6.41 Table 10. Software Compatibility Matrix Versions 5.30 and Above - (continued) Software/Firmware Assembly Part Number Software, PXS Panel Appl 6.4 none Software, MB4 Panel Appl 6.3 none Software, MB4 Panel Appl 6.4 none Software, SCP Panel Appl 6.3 none Software, SCP Panel Appl 6.4 none Software, EDP Panel Appl 6.4 none a Analog R5.30 4/95 R5.37 1/96 R6.0 4/96 R6.3 6/97 R6.4 12/97 R6.41 5/98 R3.06 11/93 R3.07 12/93 R4.05 6/94 R4.
Software, Hardware, and Firmware Required Table 11. Software Compatibility Matrix Versions 1.0 to 4.06 - (continued) Software/Firmware Assembly Part Number R1.0 Firmware, HX_NC App Even 151109-00 Firmware, HX_NC App Even Firmware, HX_NC App Odd Firmware, HX_NC App Odd Firmware, Node Cntrl R3 Boot Rom (U18) Firmware, Node Cntrl R3 Boot Rom (U17) Firmware, Node Controller App Even Firmware, Node Controller App Odd Firmware, Node Controller App Ver 2.0 (U16) Firmware, Node Controller App Ver 2.
Version 6.41 Hardware Compatibility Matrix The following table lists hardware assembly numbers for the various Series 7000 Software Releases. Matrix Element Control (MEC) circuitry on each matrix module must be at the proper revision level, or later, to take full advantage of 6.4 features. Check the table for minimum versions (-xx) of modules to fully support R6.4 Table 12. Series 7000 Hardware Compatibility Hardware Assembly Part # R3.0 R3.05 R3.06 R3.07 R3.
Software, Hardware, and Firmware Required Table 12. Series 7000 Hardware Compatibility - (continued) Hardware Assembly Part # Controller Frame 092844 BPS-32 Control Panel 092845 -02 -03 -06 092846 -02 -03 -06 092847 -02 -03/-12/-22/32 -06/-15/-25/-35 Dual Under Monitor Display a 092852 -02 -03/-12/-22/32 -06/-15/-25/-36 Triple Under Monitor Display a 092876 -30 -33 UCP Control Panel 092857 -03 -06 MB8 Control Panel Under Monitor Display a R3.0 R3.05 R3.06 R3.07 R3.1 R4.
Version 6.41 Hardware, Firmware, and Software Installation Installation information for Version 6.41 MCPU Update Kits in systems that currently run Version 3.x, 4,x, 5.x, or 6.x Software. Requirements 16 ■ -02 version Control Frame (092844-02) with Ethernet power modification, SMS-DV64X64, or SMS-64V Compact System with Controller ■ For systems that contain the NC Expansion option, the 062938-01 version Node Controller Expansion Boards (062938-00 modules do not work) ■ A PC running Windows 3.
Hardware, Firmware, and Software Installation Procedures SMS-64V with Amezi Serial Control? YES Install UART Mezzanine NO Use Figure 1, and Table 13 to determine which of the following procedures are needed to upgrade your current system. Table 13. Upgrade Table Versions Save Current Configuration 6.x Install Application Software Software Version 3.x, 4.x, or 5.x? NO YES Install MCPU Firmware & Hardware Software Version 3.x, or 4.
Version 6.41 Install UART Mezzanine This is to be used when upgrading SMS-64V Systems with Amezi Serial Control only. Some Compact System (SMS-64V) configurations may use a Controller Module with an Amezi card in the #2 mezzanine position running Native Protocol. These systems do not have the capability to run a system terminal. To install new MCPU Application Software on these systems, the Amezi mezzanine must be temporarily replaced with a UART mezzanine to run the system terminal.
Hardware, Firmware, and Software Installation 2. Telnet into the System Diagnostic Interface. Enter the following command: For MCPU #1 C:\> telnet sms7000 For MCPU #2 C:\> telnet sms7000b 3. Press RETURN to see the SMS7000> System Diagnostic prompt. 4. Enter the following commands at the System Diagnostic prompt: SMS7000> del “slip.ini” SMS7000> del “console.ini” 5. Verify the above files have been deleted by examining a directory listing of the FLASH file system.
Version 6.41 Save Current Configuration This is to be used when upgrading from all versions. Using the version 3.x, 4.x, 5.x, or 6.x Configuration Editor (GUI) on your Windows PC save the configuration. To Save the Current Configuration File: 1. Open Windows. 2. Double-click on the SMS 7000 icon to access the Connect to Router window. Figure 3. GUI Icon, Connect to Router, and Transfer Configuration Windows 3.
Hardware, Firmware, and Software Installation 6. Under the File menu, select Save As to save a copy of the current configuration to the GUI PC hard drive or to other media such as a floppy diskette. SERIES 70 File OnLine New Open... Save Save As... Delete Exit Figure 5. Save As Menu Install Application Software This is to be used when upgrading from all versions.
Version 6.41 Figure 7. Custom Installation Window Click on the check-boxes to select which Series 7000 options you need to load onto your PC. To select a different directory to store your Series 7000 software, press the Set Location button. The Installation Location dialog box displays: Figure 8.
Hardware, Firmware, and Software Installation For an explanation of the installation options, press the HELP button, and the following help screen displays. Figure 9. Custom Installation Help Window If you install the PC GUI software, the installation procedure may change your NFS directory. The system asks you to respond with this dialog box: Figure 10. PC-NFS Path Specification Window You may bypass NFS checking by selecting the CANCEL button.
Version 6.41 The installation procedure asks you to insert other disks as needed with a dialog box similar to the following: Figure 11. Insert Next Disk Window If you install the Series 7000 software on a PC that already has a prior software version, the system may make backups of your previous files. If it does, the system displays the following information screen: Figure 12.
Hardware, Firmware, and Software Installation Install MCPU Firmware and Hardware This is to be used when upgrading from versions 3.x, 4.x and 5.x only. CAUTION Use ground straps and take appropriate ANTI-STATIC precautions when handling modules and IC components. 3505-02 J1 Connector Ver. 3 Sys. Only PLD - SU9 052874-04 µProc. - SU8 80960CF PLD - SU48 051026-01 960 MPU Comm.
Version 6.41 Table 14. New MCPU Firmware and Hardware Quantity per Board New Firmware, Hardware Part Number Board(s)/ Part Number MCPU FLASH SIMMs (J1, J2) (Ver. 3 & 4 systems only) 2 160135-00 MCPU/062876-xx MCPU 80960CF (SU8) MicroProcessor (E0 STEP) (Ver. 3, 4, & 5 systems only) 1 SC2813-00 MCPU/062876-xx Description Install the MCPU(s). The FLASH ROMs have been preloaded with MCPU application software.
Hardware, Firmware, and Software Installation MCPU Network Parameters Configuration This is to be used when upgrading from versions 3.x and 4.x only. If not already connected, connect a dumb terminal to the system CTL port. It is necessary to configure your MCPU network parameters to allow proper communication of network devices such as the GUI PC. Verify that the left MCPU (MCPU #1) is up and running as primary (yellow LED on).
Version 6.41 Program MCPU Software This is to be used when upgrading from versions 5.x and 6.x only. Application software version 6.41 must be loaded into MCPU FLASH for systems updating from 5.x and 6.x to work properly. You must remove the redundant MCPU from the frame while booting from the Ethernet or SLIP device. You will perform Step 4 for the primary MCPU and then repeat it for any redundant MCPU. The redundant MCPU will use slightly different names and IP addresses.
Hardware, Firmware, and Software Installation Inquire of the Main MCPU parameters first, and then with the Backup MCPU installed and the Main MCPU removed repeat the process. The Back-up MCPU uses slightly a different name and IP address. In the example below, Backup MCPU(s) name and IP address are indicated in brackets [] to the right of the Main MCPU entries.
Version 6.41 3. Change the Boot Device back to MCPU Flash ROM Using the reboot or booted command, change the boot device back to fi for Flash. Using the p command, verify that the boot parameters are set to the following: boot device: fi processor number: 0 host name: PC file name: SMS inet on ethernet (e): 192.0.2.2:ffffff00 [192.0.2.3:ffffff00] inet on backplane (b):[blank] host inet (h): 192.0.2.
Hardware, Firmware, and Software Installation Option 1 Select option 1 for the normal load of universal and programmed button panels plus the custom panels such a cubicle or studio, machine control, source ID, client-server and under monitor display types. This option includes the Non GVP alien matrixes via native protocol, however, GVP matrices (Hx GPI, 440, Performer, 20-Ten via azgvg.bin) are excluded. The excluded GVP alien matrix support may be loaded individually from the C:\SMS7000 directory.
Version 6.41 Option 2 Select option 2 for the alternate load which includes both GVP and Non GVP alien matrix support. Option 2 requires approximately 1,770,000 bytes in the target MCPU. Since the MCPU file system is approximately 2, 080,000 bytes, this leaves approximately 300,000 bytes for config and other user files. Option 2 loads the following files: csos.bin stmg.bin mb8.mot fl.mot mb4.mot Note amezi.bin ucp.mot pxs.mot progcp.red scp.mot azgvg.bin bps32.mot pxd.mot prognc.red CLF.
Hardware, Firmware, and Software Installation To aid in panel-type identification excluded from option 2, refer to the panel descriptions in the following list: SVR.MOT CLN.MOT CLF.MOT COS.MOT MCO.MOT SID.MOT SCP.MOT MB4.MOT UMD.MOT EDP.
Version 6.41 Flash Memory Limitations and Recovery Procedure If file space is not available on the target MCPU flash file system, the PC monitor may display the following error: ---> PORT (etc.) ---> STOR file.name (which failed to load to the MCPU file system) netout: Socket is not connected Error in input file ---> QUIT C:\SMS7000> Note It will save much aggravation if you take care not to run out of flash memory.
Hardware, Firmware, and Software Installation Loading EDP Panel Software Into Nonvolatile Memory The Eight Destination Paging (EDP) panel software is not loaded as part of either Option 1 or Option 2. To load EDP software: ● Make sure there is enough room (200000 bytes) in flash memory for this software. ● To check, type C:\sms7000> dir from the diagnostic terminal to list files; ● To make space, remove unneeded control panel mot files from flash memory. For example: C:\sms7000. del mco.
Version 6.41 Because of this, the operator is required to edit the coprocessor configuration using the following procedure. 1. Start the GUI and open the configuration you saved previously. If you are opening a Version 3 configuration, you will see text in the Message Window as follows: Reading s (e.g., Reading Sources) Error on line x char y: parse error There will be one such parse error for each kind read in. They are harmless.
Hardware, Firmware, and Software Installation Load Node Controller Software This is to be used when upgrading from all versions. CAUTION This applies to systems being updated from versions 3.x, 4.x, or 5.x where the NBX boot ROM is replaced. In the following step, replacement of NBX boot ROM will cause the Node Controllers to lose their names. Note the current names so you can later restore them using the GUI Active Node Controller Rename command. 1. Program Series 7000 Node Controllers with the 6.
Version 6.41 3. Install HX NC ROMs If you have HX Node Controllers, you must remove and replace the ROM ICs containing the application. HX Node Controllers do not have FLASH ROM and therefore are not programmed using the procedure for Series 7000 Node Controllers. Table 15.
Hardware, Firmware, and Software Installation Re-Install Amezi Mezzanine This is to be used when upgrading SMS-64V Systems with Amezi Serial Control only. If your system uses an Amezi controller mezzanine board in position #2 of the MCPU mezzanines, you have placed a temporary UART in the top mezzanine slot of the MCPU to perform this update. Perform the following to re-install the Amezi. 1. At the System Diagnostic Interface, enter the following commands: SMS7000> del “console.ini” SMS7000> del “slip.
Version 6.