USER MANUAL QSDL503AD Intelligent Auto-Dial Alarm System Rev 10.28.
QSDL503AD USER MANUAL TABLE OF CONTENTS Section 1:USAGE ................................................................................................................................ 1 Section 2:FEATURES ......................................................................................................................... 1 Section 3:PACKAGE CONTENTS ...................................................................................................... 1 Section 4:SYSTEM INSTALLATION ...................
QSDL503AD USER MANUAL Section 1: USAGE Ideal for use in a home, business or warehouse environment and virtually anywhere an increased amount of anti-theft assurance is needed. This Auto-Dialing Wireless Alarm System deters unwanted intruders from entering by emitting a high pitched alarm signal if the parameters of the secured area have been breached.
QSDL503AD USER MANUAL Section 4: 4.1: SYSTEM INSTALLATION Main Control Panel 1. Connect one end of the enclosed standard telephone wire to the wire inlet on the Main Control Panel (See Picture 1) and the other end to the telephone. 2. Plug the jack of enclosed adapter into the DC plug of the Main Control Panel (See Picture 1) and connect the AC plug into a wall plug or surge protector. 3.
QSDL503AD USER MANUAL 4.3: Magnetic Window/Door Sensor Alarms 1. Position the Magnetic Window/Door Sensor Alarm (Picture 3) along the conjoining edges of any window or door you wish to protect using heavy duty double-sided adhesive tape. It is recommended to use your Magnetic Window/Door Sensor Alarms on entries and windows that are most susceptible to break-ins and vulnerable to intruders. 2.
QSDL503AD USER MANUAL 4.5: Magnetic Code Controller 1. Remove the battery compartment cover on the front of the Magnetic Code Controller (Picture 5), insert 3 “AA” alkaline batteries and replace the battery compartment cover. 2. Decide on the location you would like to attach your Magnetic Code Controller. It is recommended to use a door that is central to your home and in an area that is easy for you to access. 3.
QSDL503AD USER MANUAL Section 5: SETTING UP THE MAIN CONTROL PANEL Display Screen Indicator Light Record Panic (Alarm) Code Microphone Lock Keypad (Picture 7) After loading the batteries in the Wireless Indoor Lighted Siren, Infrared Sensors and Magnetic Window/Door Sensors, you are now ready to configure the Main Control Panel. Turning the Main Control Panel ON will generate the message NO-SAVE in the Display Panel.
QSDL503AD USER MANUAL Section 6: SETTING UP THE MAGNETIC CODE CONTROLLER Alarm Button – Press to Instantly Activate the Alarm in the event of an emergency Arm Button – Press to set Your Magnetic Code Controller in Arm Mode (Picture 8) Pressing the ARM button once on the Magnetic Code Controller will activate it after 30 seconds. After 30 seconds, the Controller is actively on and protecting the doorway that you chose to mount it on.
QSDL503AD USER MANUAL Section 7: TURNING YOUR SYSTEM ON 1. Once you have configured your Main Control Unit and your Magnetic Code Controller, you can now use your alarm system. With the power to your Main Control Unit on, press the ARM button on the Magnetic Code Controller (Picture 8). You will hear the Main Control Unit and the Wireless Indoor Lighted Siren respond by beeping to let you know that they are on and armed.
QSDL503AD USER MANUAL Section 8: SETTING UP THE ADDITIONAL ACCESSORIES To enable communication between the Main Control Unit and the various accessories, you must follow these steps: 1. To Connect the Main Control Unit to the Wireless Indoor Lighted Siren: Press the CODE button on the front of the Main Control Unit and the CODE button on the back of the Wireless Indoor Lighted Siren simultaneously.
QSDL503AD USER MANUAL Section 9: TECHNICAL DATA Main Control Unit: Input voltage: DC6V-9V Working current: <12 m A Receive frequency: 433.5MHZ-434MHZ Infrared Sensor: • Input volts: DC4.5V (AAAx4) • Stand by current: <0.1mA • Transmission current: <8mA • Transmission frequency: 433.5MHZ-434MHZ • Transmission distance: >100m (330 ft) (open area) • Inductive distance: >5m (16 ft) (open area) • Low voltage indication: <3.1V +/- 0.1V Magnetic Window/Door Sensor Alarm: • Input volts: DC4.
QSDL503AD USER MANUAL Section 10: LOCATION SUGGESTIONS Wireless Indoor Lighted Siren – Infrared Sensor Magnetic Code Controller 10 | P a g e
QSDL503AD USER MANUAL Section 11: DIAGRAM 11 | P a g e
QSDL503AD USER MANUAL Q-SEE PRODUCT WARRANTY Thank You for Choosing a Q-See Product! All of our products are backed by a conditional service warranty covering all hardware for 12 months from the date of purchase. Additionally, our products also come with a free exchange policy that covers all manufacturing defects for one month from the date of purchase.
QSDL503AD USER MANUAL CUSTOMER INFORMATION CARD User’s Name Mr./Mrs. Company Name Postal Address Postal Code Phone Number E-mail Model Number of Product Serial Number of Product Purchase Date Distributor The material in this document is the intellectual property of Q-See. No part of this manual may be reproduced, copied, translated, transmitted, or published in any form or by any means without our company’s expressed written consent. 1.