Manual

Q-TECH Corporation - 10150 W. Jefferson Boulevard, Culver City 90232 - Tel: 310-836-7900 - Fax: 310-836-2157 - www.q-tech.com
11 of 27
Q-TECH
CORPORATION
QPDS-0001, Rev L, June 2013 (ECO #10851)
CLASS B+ PRODUCTS
HIGH RELIABILITY HYBRID CRYSTAL CLOCK OSCILLATORS
2.5 to 5.0Vdc - 15kHz to 350MHz
Test Description
MIL
Standard
Method Condition Qty Comments
Internal Visual 883 2017 Class H 100%
Stabilization Bake 883 1008 C 100% 48 hours at +150°C
Temperature Cycling 883 1010 B 100% 10 cycles
Constant Acceleration 883 2001 A 100% Y1 direction only (5,000g’s)
Particle Impact Noise Detection (PIND) 883 2020 B 100%
5 passes minimum
(see Note 1)
Pre Burn-In Electrical Refer to Table III-a and Detail Specification 100%
Burn-In 883 1015
+125°C
for 160 hours
100% With load and nominal supply voltage
Final Electrical Refer to Table III-a and Detail Specification 100%
Percent Defective Allowance (PDA) 38534
PDA=2% (Supply Current only)
Seal Fine Leak 883 1014 A1 100%
Seal Gross Leak 883 1014 C 100%
External Visual 883 2009 100%
Screening - Option B (Modified MIL-PRF-55310, Level B)
(Example: QT178LD10B-50.000MHz)
NOTES:
1. PIND testing shall be performed using five (5) independent passes and all failures found at the end of each pass are rejected. The
survivors of the last pass are acceptable.
2. 100% Group A QCI test per MIL-PRF-55310
Parameters
Pre BI
at 25ºC
Pre BI
Low Temp
Pre BI
High Temp
Post BI
at 25ºC
Post BI
Low Temp
Post BI
High Temp
Output frequency
Frequency/temperature stability
Frequency/voltage stability
Input current
Output voltage
Waveform
Duty cycle
Rise and fall times
Start up time
Tristate Function (if applicable)
Table III-a
Electrical Test - Measurement Requirements
QCI (per MIL-PRF-55310, Level B or S) (To be specified on Purchase Order)
• Group B (AgingTest)
• Group C (See details on Table VIII)
QCI Options (per MIL-PRF-38534, Class K-Modified)
• Group B Inspection per MIL-PRF-38534, Class K-Modified (See details on Table V)
• Group C Inspection per MIL-PRF-38534, Class K-Modified (Delta Limits per Table II) (See details on Table VI)
• Group D Inspection per MIL-PRF-38534, Class K-Modified (See details on Table VII)
Table III
Back To Summary