Owner manual

MIL-PRF-55310/33C
5
Terminal strength: Method 211 of MIL-STD-202, test condition A.
Applied force: 8 ounces each terminal.
Frequency-environmental tolerance: Not applicable.
NOTES:
1. For C
CL
= 15 pF ±5 percent.
2. For R
CL
= 10 kΩ ±5 percent.
3. C
CL
includes scope capacitance.
FIGURE 2. Load test circuit.