Owner manual

MIL-PRF-55310/38B
3
TABLE I. Dash numbers and operating characteristics.
1/ Temperature range A applicable for product level B oscillators only.
2/ Maximum input current for no load condition.
3/ See figure 3.
Frequency-temperature tolerance (one-half temperature cycle, referenced to frequency measured at +23°C ±1°C,
immediately prior to starting of the test): See table I. Measurements taken at ten equally spaced increments over
the specified operating temperature range. 1/
Frequency-voltage tolerance: ±4 ppm maximum for a ±10 percent change in supply voltage. Measurements taken
at reference temperature and operating temperature range end points.
1/ For the purpose of transitioning this device to MIL-PRF-55310
, ‘Frequency stability versus temperature’ has been
renamed ‘Frequency-temperature tolerance’. The verification requirements of ‘initial frequency-temperature
accuracy (one-half temperature cycle)’ shall apply except that frequency measurements shall be referenced to the
frequency measured at +23°C ±1°C (f
ref
) instead of to the nominal frequency (f
nom
).
Dash
number
Input
current
Pulse characteristics
Initial
accuracy
Frequency-temperature
tolerance (ppm) 1/
(max) 2/
Rise and
fall times
(max) 3/
Duty cycle
min-max
3/
at +23°C
±1°C
-55°C
to
+125°C
-55°C
to
+105°C
-20°C
to
+70°C
A
B
C
01
6 mA
6 ns
45% to 55%
±15 ppm
±50
ppm
±40
ppm
±25
ppm
04
6 mA
6 ns
45% to 55%
±25 ppm
±100
ppm
±80
ppm
±50
ppm
11
10 mA
5 ns
40% to 60%
±15 ppm
±50
ppm
±40
ppm
±25
ppm
14
10 mA
5 ns
40% to 60%
±25 ppm
±100
ppm
±80
ppm
±50
ppm
21
15 mA
5 ns
40% to 60%
±15 ppm
±50
ppm
±40
ppm
±25
ppm
24
15 mA
5 ns
40% to 60%
±25 ppm
±100
ppm
±80
ppm
±50
ppm
31
20 mA
3 ns
40% to 60%
±15 ppm
±50
ppm
±40
ppm
±25
ppm
34
20 mA
3 ns
40% to 60%
±25 ppm
±100
ppm
±80
ppm
±50
ppm
41
30 mA
3 ns
40% to 60%
±15 ppm
±50
ppm
±40
ppm
±25
ppm
44
30 mA
3 ns
40% to 60%
±25 ppm
±100
ppm
±80
ppm
±50
ppm
51
40 mA
3 ns
40% to 60%
±15 ppm
±50
ppm
±40
ppm
±25
ppm
54
40 mA
3 ns
40% to 60%
±25 ppm
±100
ppm
±80
ppm
±50
ppm
61
45 mA
3 ns
40% to 60%
±15 ppm
±50
ppm
±40
ppm
±25
ppm
64
45 mA
3 ns
40% to 60%
±25 ppm
±100
ppm
±80
ppm
±50
ppm