Environmental Specifications
Q-Tech Standard Screening similar to (MIL-PRF-55310) is available. Q-Tech can also customize screening and test procedures to meet
your specific requirements. The packages are designed and processed to exceed the following test conditions:
Environmental Test Test Conditions
Initial Accuracy at Reference Temperature MIL-PRF-55310, Type 4, Class 3
Frequency Warm-up MIL-PRF-55310, Type 4, Class 3
Initial Frequency-Temperature Accuracy MIL-PRF-55310 (4.8.10.1)
Frequency-Voltage Tolerance MIL-PRF-55310
Frequency-Load Tolerance MIL-PRF-55310
Phase Noise Steady-State MIL-PRF-55310
Phase Noise Random Vibration MIL-PRF-55310
Output Power (Sinusoidal Waveform) MIL-PRF-55310
Output Logic Voltage Levels (Square wave ) MIL-PRF-55310
Rise Time and Fall Time (Square wave ) MIL-PRF-55310
Duty Cycle (Square wave ) MIL-PRF-55310
Harmonic and Sub-harmonic Distortion MIL-PRF-55310
Spurious Response MIL-PRF-55310
Oven Input Current-Power MIL-PRF-55310, Type 4, Class 3
Temperature Cycling MIL-STD-883, Method 1010, Cond. B
Constant Acceleration MIL-STD-883, Method 2001, Cond. A, Y1
Seal Fine Leak MIL-STD-883, Method 1014, Cond. A & C
Burn-in 240 hours, At highest operating temperature with load
Aging 30 days, MIL-PRF-55310, Type 4, Class 3
Random Vibration MIL-STD-883, Method 2026
Shock, Non Operating MIL-STD-883, Method 2002
Thermal Shock, Non Operating MIL-STD-202, Method 107, Cond. B
Ambient Pressure MIL-STD-202, 105, Cond. G, 5 minutes dwell time minimum
Resistance to Solder Heat MIL-STD-202, Method 210, Cond. C
Terminal Strength MIL-STD-202, Method 211, Cond. C
Resistance to Solvents MIL-STD-202, Method 215
Solderability MIL-STD-202, Method 208
ESD Classification MIL-STD-883, Method 3015, Class 1HBM 0 to 1,999V
Non-destructive Bond Pull MIL-STD-883, Method 2023
Please contact Q-Tech for higher shock requirements