- Manganese : In test on eyes irritation with rabbits, eyes irritations were not observed.(OECD TG 405,
GLP)
Respiratory sensitization :
- Aluminum : Al2O3 was the least inflammatory material tested and led to only weak effects on the
mouse lung. (Read across; Aluminium oxide)
- Carbon black : In respiratory sensitization test with mice(female), it did not induce respiratory
sensitization.
Skin sensitization :
- Cobalt hydroxide oxide : In the skin sensitization test using mouse, this material was not skin
sensitizing.(OECD Guideline 429, GLP)
- Graphite : In the skin sensitization test using mice, the test material was not skin sensitization.
(OECD Guideline 429, GLP)
- Aluminum : In test with guinea pigs, it can be concluded that aluminium oxide has no sensitisation
potential under the experimental conditions. (Read across; Aluminium oxide)
- Lithium carbonate;Lithane : In the skin sensitization test using guinea pig, this material was not skin
sensitizing. (OECD Guideline 406, GLP)
- Copper : In maximization test on skin sensitization with guinea pig, skin sensitization was not
observed. (OECD TG 406, GLP)
- Ethyl methyl carbonate : In the skin sensitization test using guinea pig, this material was not skin
sensitizing. (OECD Guideline 406, GLP)
- Tricobalt tetraoxide : In a LLNA with guinea-pigs, this substance was not classified as skin
sensitiser.(OECD TG 429, GLP)
- 1,3-Dioxolan-2-one : In the skin sensitization test using guinea pig, this material was not classified.
(OECD Guideline 406, GLP)
- Polyethylene : No reactions were observed in skin sensitization test with guinea pigs.
- Carbonic acid diethyl ester : In local lymphnode assay with mice, diethyl carbonate was shown to
have no sensitising potential.(OECD TG 429, GLP)
- Lithium hexafluorophosphate(1-) : In the skin sensitization test using mice, the test material was not
skin sensitization. (OECD Guideline 429, GLP)
- Butanedinitrile : In the skin sensitization test using mice, the test material was not classified. (OECD
Guideline 429, GLP)
- Carbon black : In skin sensitization test with guinea pig(female), it did not induce skin sensitization.
(OECD Guideline 406, GLP)
- Fe : In the test using guinea pigs, the test substance was not considered to be a dermal sensitizer in
guinea pigs.(read across; FeO, Fe2O3)
- Nickel; Raney nickel : Nickel hypersensitivity dermatitis may be initiated by contact with nickel on the
skin.
- Manganese : In the test using mouse, the test substance was not considered to be a dermal
sensitizer in mouse.(OECD TG 429, GLP)
Carcinogenicity :
IARC
- Cobalt and cobalt compounds : Group 2B
- Carbon black : Group 2B
- Polyethylene : Group 3
- Nickel : Group 2B
NTP
- Iron : Present
- Carbon black : Present
- Nickel : R
OSHA