Safety Data Sheets (SDSs) Safety Data Sheets (SDSs) Client Add. of Client Xinxiang Hongli Power Technology Co., Ltd. Dayang Village South, Zhaipo Town, Xinxiang, China Description Cylindrical Lithium-ion Rechargeable Cell Model /Type ICR18650-1200mAh Manufacturer Xinxiang Hongli Power Technology Co., Ltd. Add. of Manufacturer Dayang Village South, Zhaipo Town, Xinxiang, China Nominal Voltage 3.7V, 1200mAh, 4.
Safety Data Sheets (SDSs) 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING Product Identifier Product name: Cylindrical Lithium-ion Rechargeable Cell Model: ICR18650-1200mAh Other means of identification Synonyms:none Recommended use of the chemical and restrictions on use Recommended Use:Used in portabl electronic equipments; Uses advidsed against: a) Do not dismantle, open or shred secondary cells or batteries. b) Do not expose cells or batteries to heat or fire.
Safety Data Sheets (SDSs) Emergency telephone number Company Emergency Phone Number: 0755-8968998 2. HAZARDS IDENTIFICATION Classification No harm at the normal use.
Safety Data Sheets (SDSs) Other information No information available. 3. COMPOSITION/INFORMATION ON INGREDIENTS Chemical characterixation: Mixtures Description: Product: Consisting of the following components. Common Chemical Name Concentration (%) CAS Number Lithium Cobalt Oxide (CoLiO2) 30 12190-79-3 1,1-Difluoroethylene polymer 3.5 24937-79-9 Aluminum foil 10 7429-90-5 Graphite 20.5 7782-42-5 Sodium carboxymethyl cellulose 4.4 9004-32-4 Styrene-Butadiene polymer 4.
Safety Data Sheets (SDSs) Indication of any immediate medical attention and special treatment needed Notes to Physician Treat symptomatically 5. FIRE-FIGHTING MEASURES Suitable Extinguishing Media CO2, dry chemical powder, water spray. Unsuitable Extinguishing Media:No information available. Specific Hazards Arising from the Chemical Formation of toxic gases is possible during heating or in case of fire.
Safety Data Sheets (SDSs) Methods for Containment Prevent further leakage or spillage if safe to do so. Methods for Cleaning up Use personal protective equipment. Dam up. Cover liquid spill with sand, earth or other Non combustible absorbent material. Pick up and transfer to properly labeled containers. Clean contaminated surface thoroughly. 7. HANDLING AND STORAGE Precautions for safe handling Handling Handle in accordance with good industrial hygiene and safety practice.
Safety Data Sheets (SDSs) Use adequate general or local exhaust ventilation to keep airborne concentrations below the permissible exposure limits. Ensure adequate ventilation. Individual protection measures, such as personal protective equipment Eye/Face Protection: Tightly sealed goggles Body protection: Protective work clothing.
Safety Data Sheets (SDSs) Upper/lower flammability or explosive limits Not determined. Vapor Pressure: Not determined. Vapor Density: Not determined. relative density: Not determined. Solubility in Water: Not determined. Solubility in other solvents Not determined. n-octanol/water partition coefficient Not determined. Auto-ignition temperature Product is not self-igniting. Decomposition temperature Not determined. Odout threshold Not determined. Evaporation rate Not determined.
Safety Data Sheets (SDSs) 12. Ecological Information Toxicity: Acquatic toxicity: No further relevant information available. Persistence and degradability: No further relevant information available. Bioaccumulative potential: No further relevant information available. Mobility in soil: No further relevant information available. Results of PBT and vPvB assessment PBT: Not applicable. vPvB: Not applicable. Other adverse effects: No information available. 13.
Safety Data Sheets (SDSs) The lithium ion batteries according to Section II/Section IB of PACKING INSTRUCTION 965, or Section II of PACKING INSTRUCTION 966~967 of the Dangerous Goods regulations 58th Edition may be transported. The packaging shall be adequate to avoid mechanical damage during transport, handling and stacking. The materials and pack design shall be chosen so as to prevent the development of unintentional electrical conduction, corrosion of the terminals and ingress of moisture.