Page 1 of 10 Pages No.: GJW2017-2922 材料安全数据表 Material Safety Data Sheet 样 品 名 称: 锂离子电池 Name of Sample: Lithium-ion Battery 委 托 单 位: 深圳市博富能电池有限公司 Commissioner: Shenzhen Bofuneng Battery Co., Ltd. 威凯检测技术有限公司 Vkan Certification & Testing Co., Ltd.
Ref, No.: GJW2017-2922 Page 2 of 10 Pages 材料安全数据表 Material Safety Data Sheet 1. 化学品及企业标识 Chemical product and company identification 样品名称 Name of Sample 样品型号 Type/Mode 委托单位 Commissioned by 锂离子电池 Lithium-ion Battery 18650 1800mAh 3.7V 1800mAh 6.66Wh 深圳市博富能电池有限公司 Shenzhen Bofuneng Battery Co., Ltd. 委托单位地址 Commissioner address 深圳市龙岗区龙城街道五联社区朱古石路春洋工业园 A、E 栋 A&E Building, Chunyang Industrial Park, Zhugushi Road, Wulian,Longcheng, Longgang, Shenzhen,P. R.
Ref, No.: GJW2017-2922 Page 3 of 10 Pages 2. 成分/组成信息 Composition information 材料及组分 Material or ingredient 氧化锂钴 Lithium Cobalt Oxide 丁苯橡胶 SBR (PE)聚乙烯 polyethylene 聚偏二氟乙烯 PVDF 石墨 Graphite 六氟磷酸锂 Lithium Hexafluorophoshate 碳酸乙烯酯 Ethylene carbonate 化学式 Chemical Formula CAS 号 CAS No. 重量含量 Wt % LiCoO2 12190-79-3 39.6 (C8H8.C4H6)x 9003-55-8 1.78 (CH2H4)n 9002-88-4 0.06 (CH2CF2)n 24937-79-9 1.15 C 7782-42-5 23.2 LiPF6 21324-40-3 15.35 C3H4O3 96-49-1 2.72 Cu 7440-50-8 9.
Ref, No.: GJW2017-2922 Page 4 of 10 Pages 4. 急救措施 First aid measures 眼睛:万一接触,立即用大量的清水冲洗至少 15 分钟,翻起上下眼睑,直到化学的残留物消失 为止,迅速就医。 Eye: Flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Get medical aid. 皮肤:万一接触,用大量水冲洗至少 15 分钟,同时除去污染的衣物和鞋子,迅速就医。 Skin: Remove contaminated clothes and rinse skin with plenty of water or shower for 15 minutes. Get medical aid. 吸入:立即从暴露处移至空气清新处,如果呼吸困难给予输氧,立即就医。 Inhalation: Remove from exposure and move to fresh air immediately.
Ref, No.: GJW2017-2922 Page 5 of 10 Pages plastic bag and put into a steel can. The preferred response is to leave the area and allow the battery to cool and vapors to dissipate. Provide maximum ventilation. Avoid skin and eye contact or inhalation of vapors. Remove spilled liquid with absorbent and incinerate.
Ref, No.: GJW2017-2922 Page 6 of 10 Pages 防护手套 正常使用条件下不必考虑。 Protective Gloves Not necessary under conditions of normal use. 其他防护服装或设备 正常使用条件下不必考虑。 Other Protective Clothing or Equipment Not necessary under conditions of normal use. 电池开阀试验时应做好个人防护 呼吸防护,防护手套,防护服装和有护边的安全玻璃罩都是要准备的。 Personal Protection is recommended for venting battery Respiratory Protection, Protective Gloves, Protective Clothing and safety glass with side shields. 9.
Ref, No.: GJW2017-2922 Page 7 of 10 Pages 在潮湿的条件下。 Conditions to Avoid : Heat above 70°C or incinerate. Deform. Mutilate. Crush. Disassemble. Overcharge. Short circuit. Expose over a long period to humid conditions. 应避免的材料:氧化剂,碱,水。 Materials to avoid: Oxidising agents, alkalis, water. 危险分解物:有毒烟雾,并可能形成过氧化物。 Hazardous Decomposition Products : Toxic Fumes, and may form peroxides. 聚合危害:不适用 Hazardous Polymerization : N/A.
Ref, No.: GJW2017-2922 Page 8 of 10 Pages 法规处理。 Do not incinerate, or subject cells to temperature in excess of 70°C, Such abuse can result in loss of seal leakage, and/or cell explosion. Dispose of in accordance with appropriate local regulations. 14.
Ref, No.
Ref, No.: GJW2017-2922 Page 10 of 10 Pages 注 意 事 项 Important Notice 1. 本鉴定报告书仅对送检样品有效。 This report is valid for the tested samples only. 2.申请人提供的样品须与实际运输货物一致。 The goods of transporting must be insure conformity with the testing samples. 3.本鉴定报告书无检验单位印章、骑封章无效。 This report is invalid without the official stamp of CVC and Paging seal of CVC. 4.本鉴定报告书无批准人、审核人及鉴定人签名无效。 This report is invalid without the signatures of Ratifier, Reviewer and Testing engineer. 5.本鉴定报告书涂改无效。 This report is invalid if altered. 6.
Shenzhen SEM.Test Technology Co., Ltd. 1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Safety Data Sheet Road, Bao'an District, Shenzhen, P.R.C. (518101) SDS Prepared For : AF T SAFETY DATA SHEET Zhangzhou Wah Fu New Energy Technology Co., Ltd. Zhangzhou City, Fujian Province Yunling Yunling Industrial Development Zone LED Avenue. Prepared By : Shenzhen SEM.Test Technology Co., Ltd. DR 1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Road, Bao'an District, Shenzhen, P.R.C.
Shenzhen SEM.Test Technology Co., Ltd. 1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Safety Data Sheet Road, Bao'an District, Shenzhen, P.R.C. (518101) Section 1-Chemical Product and Company Identification Product: li-ion battery Common name: li-ion battery Model: 18650 Lithium ion 7.4V 6000mAh/44.4wh Rating of battery: 7.4V, 6000mAh, 44.4Wh Trademark: N/A Weight: 283g Shape and Physical Dimension (mm): Φ69.1*55.3*37.4mm Manufacture: Zhangzhou Wah Fu New Energy Technology Co., Ltd.
Shenzhen SEM.Test Technology Co., Ltd. 1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Safety Data Sheet Road, Bao'an District, Shenzhen, P.R.C. (518101) Emergency Overview Signal word Hazard Statements Causes skin irritation Causes serious eye damag May cause cancer Suspected of damaging fertility or unbom exposure AF T Contains gas under pressure; may explode if heated This product is an article which contains a chemical substance.
Shenzhen SEM.Test Technology Co., Ltd. 1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Safety Data Sheet Road, Bao'an District, Shenzhen, P.R.C. (518101) Skin IF ON SKIN: Wash with plenty of soap and water If skin irritation occurs: Get medical advice/attention Take off contaminated clothing and wash before reuse Precautionary Statements - Storage No information available.
Shenzhen SEM.Test Technology Co., Ltd. 1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Safety Data Sheet Road, Bao'an District, Shenzhen, P.R.C. (518101) The battery is not hazard with eye and skin contact under normal circumstance. In case of the enclosure is damaged, the battery can not be used and touched. It is safety except that the battery is damaged by fire or rupture.
Shenzhen SEM.Test Technology Co., Ltd. 1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Safety Data Sheet Road, Bao'an District, Shenzhen, P.R.C. (518101) extinguishment. Section 6- Accidental Release Measures Personal precautions, protective equipment and emergency procedures: If the battery is released, remove personnel from area until fumes dissipate. Provide maximum ventilation to clear out hazardous gases. The preferred response is to leave the area and allow the vapors to dissipate.
Shenzhen SEM.Test Technology Co., Ltd. 1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Safety Data Sheet Road, Bao'an District, Shenzhen, P.R.C. (518101) If the batteries are subject to storage for such a long term as more than 3 months, it is recommended to recharge the Li-ion battery periodically.
Shenzhen SEM.Test Technology Co., Ltd. 1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Safety Data Sheet Road, Bao'an District, Shenzhen, P.R.C. (518101) (c) Individual protection measures, such as personal protective equipment Respiratory protection: No necessary under normal use. In case electrolyte leakage from the battery, protect hand with chemical resistant rubber gloves. If battery is burning, leave the area immediately.
Shenzhen SEM.Test Technology Co., Ltd. 1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Safety Data Sheet Road, Bao'an District, Shenzhen, P.R.C. (518101) Flammability (solid, gaseous): Not available Auto-Ignition temperature: Not available Decomposition temperature: Not available Self-igniting: Product is not selfigniting. Explosive properties: Risk of explosion by shock, friction, fire or other sources of ignition.
Shenzhen SEM.Test Technology Co., Ltd. 1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Safety Data Sheet Road, Bao'an District, Shenzhen, P.R.C. (518101) (d) Conditions to avoid Do not subject Li-ion Battery to mechanical shock. Keep away from open flames, high temperature. (e) Incompatible materials Strong oxidizer, strong acid. (f) Hazardous decomposition products Under fire conditions, the electrode materials can form carcinogenic nickel and cobalt oxides.
Shenzhen SEM.Test Technology Co., Ltd. 1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Safety Data Sheet Road, Bao'an District, Shenzhen, P.R.C. (518101) Mutagenic Effects: No data available. Carcinogenicity: No data available. Reproductive Toxicity: No data available. Chronic Toxicity: No data available. Target Organ Effects: No data available. Aspiration Hazard: No data available. Section 12- Ecological Information Toxicity · Aquatic toxicity: No further relevant information available.
Shenzhen SEM.Test Technology Co., Ltd. 1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Safety Data Sheet Road, Bao'an District, Shenzhen, P.R.C. (518101) Recycling options available in your local area should be considered when disposing of this product, through licensed waste carrier. c. The battery should have their terminal insulated in order to prevent short circuits during transportation to the disposal site.
Shenzhen SEM.Test Technology Co., Ltd. 1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Safety Data Sheet Road, Bao'an District, Shenzhen, P.R.C. (518101) Packing group · ADR, IMDG, IATA IB · Marine pollutant: No Special precautions for user: Warning: Miscellaneous dangerous substances and articles. · Danger code (Kemler): · Transport in bulk according to Annex II of MARPOL73/78 and the IBC Code: Not applicable.