User's Manual
Table Of Contents
- 1 Read This First
- 2 Safety Information
- 3 Overview
- 4 Preparing the System
- Inserting a microSD Card
- Using the Stand
- Charging the System
- Connecting the Transducer
- Removing the Transducer
- Using the System On The Go
- Using the Wheel Brakes
- Placing the Transducer Holder
- Mounting the System to the System Cart
- Adjusting the System Cart Height
- Connecting an External Printer
- Tilting the System
- Unmounting the System From the System Cart
- Moving the System
- Outputting the System Display to an HDMI-Enabled TV or Monitor
- Supported External Printers
- 5 Using the System
- Turning On/Off the System
- Logging Into the System
- Launching the Main Screen
- Setting the System Time and Date
- Controlling the System
- Setting the System Language
- Identifying the Main Screen Layout
- Switching the Control Panel Pages
- Managing the System Power
- Managing Disk Space
- Network Configuration
- DICOM Configuration
- 6 Performing an Exam
- Starting a New Exam
- Adding a New Patient
- Loading a Worklist
- Selecting a Preset
- Setting the Transducer Orientation
- Selecting/Switching a Scan Mode
- Adjusting the Displayed Image
- Freezing an Image
- Adding Annotations
- Adding Measurements
- Saving and Printing the Image
- Reviewing the Image
- Exporting the Exam
- Managing the Exam List
- Ending the Exam
- 7 Using Image Controls
- 2D Mode Image Controls
- Overview
- Adjusting Gain
- Adjusting Frequency
- Adjusting Time Gain Compensation (TGC)
- Adjusting the Scan Depth
- Adjusting the Focus Depth, Focal Zone and Focal span
- Adjusting Dynamic Range
- Using Tissue Harmonic Imaging (THI)
- Adjusting Persistence
- Adjusting Sharpness and Smoothing
- Adjusting Gray Map
- Adjusting Chroma Map
- Adjusting Steer Angle
- Adjusting the Sector Width and Position
- Adjusting Power
- Using Trapezoidal Imaging
- Adjusting Density
- Using Compound Imaging
- Using ENV (Enhanced Needle Visualization)
- Color/CPA Mode Image Controls
- M-Mode Image Controls
- Spectral Doppler Mode Image Controls
- 2D Mode Image Controls
- 8 System Customization and Service
- Customizing Your System
- Configuring Security Policies
- Servicing your system
- Reinstalling Software
- Checking the Software Version
- Checking the System’s Serial Number
- Checking the Tablet’s Serial Number
- Checking the License Status
- Resetting User Settings
- Backing Up System Settings and Patient Data
- Restoring System Settings and Patient Data
- Resetting Your System
- Testing the System
- Exporting System Logs
- Reading the User Manual
- 9 Transducers
- 10 Transducer Care
- 11 System Maintenance
- 12 Appendix
InnoSight Ultrasound System
Warnings
1 edii
2
P6992-4, EN, 16/12/6
Do not use the system for purposes other than those intended and expressly stated above Do not
misuse the system, and do not use or operate the system incorrectly
Installation, use, and operation of the system are subject to the law in the jurisdictions in which it is
used Install, use, and operate the system only in such ways that do not conflict with applicable laws or
regulations, which have the force of law Use of the system for purposes other than those intended and
expressly stated here, as well as incorrect use or operation, may relieve us or our agents from all or some
responsibilities for resultant noncompliance, damage, or injury
System users are responsible for image quality and diagnosis Inspect the data that is being used
for the analysis and diagnosis, and ensure that the data is sufficient both spatially and temporally
for the measurement approach being used
Warnings
Before using the system, read these warnings and Chapter 2 Safety Information
Do not attempt to disassemble or modify the system There are no user serviceable parts inside
this system Necessary modifications must be made only by the manufacturer or its designated
agents
Do not allow any liquid to get inside this system Water and moisture may cause short-circuit to
the electronic components and lead to malfunctions
Do not drop or apply shock/vibration to this system Strong impacts may damage the components
inside
Do not cut, bend, modify, place heavy objects, or step on the cable of the power adapter
Otherwise the external insulation may be damaged and result in short-circuit or fire
Do not use this system near strong electromagnetic sources, such as a microwave oven The
electromagnetic interference may cause this system to malfunction
To avoid electrical shock, use only supplied power cords and connect only to properly grounded
wall (wall/mains) outlets
The system should not be used adjacent to or stacked with other equipment If adjacent or
stacked use is necessary, the system should be observed to verify normal operation in the
configuration in which it will be used
Upgrades and Updates
Philips is committed to innovation and continued improvement Upgrades may be announced that consist
of hardware or software improvements Updated user information will accompany those upgrades