User's Manual
Table Of Contents
- 1 Read This First
- 2 Safety Information
- 3 Overview
- 4 Preparing the System
- Inserting a microSD Card
- Using the Stand
- Charging the System
- Connecting the Transducer
- Removing the Transducer
- Using the System On The Go
- Using the Wheel Brakes
- Placing the Transducer Holder
- Mounting the System to the System Cart
- Adjusting the System Cart Height
- Connecting an External Printer
- Tilting the System
- Unmounting the System From the System Cart
- Moving the System
- Outputting the System Display to an HDMI-Enabled TV or Monitor
- Supported External Printers
- 5 Using the System
- Turning On/Off the System
- Logging Into the System
- Launching the Main Screen
- Setting the System Time and Date
- Controlling the System
- Setting the System Language
- Identifying the Main Screen Layout
- Switching the Control Panel Pages
- Managing the System Power
- Managing Disk Space
- Network Configuration
- DICOM Configuration
- 6 Performing an Exam
- Starting a New Exam
- Adding a New Patient
- Loading a Worklist
- Selecting a Preset
- Setting the Transducer Orientation
- Selecting/Switching a Scan Mode
- Adjusting the Displayed Image
- Freezing an Image
- Adding Annotations
- Adding Measurements
- Saving and Printing the Image
- Reviewing the Image
- Exporting the Exam
- Managing the Exam List
- Ending the Exam
- 7 Using Image Controls
- 2D Mode Image Controls
- Overview
- Adjusting Gain
- Adjusting Frequency
- Adjusting Time Gain Compensation (TGC)
- Adjusting the Scan Depth
- Adjusting the Focus Depth, Focal Zone and Focal span
- Adjusting Dynamic Range
- Using Tissue Harmonic Imaging (THI)
- Adjusting Persistence
- Adjusting Sharpness and Smoothing
- Adjusting Gray Map
- Adjusting Chroma Map
- Adjusting Steer Angle
- Adjusting the Sector Width and Position
- Adjusting Power
- Using Trapezoidal Imaging
- Adjusting Density
- Using Compound Imaging
- Using ENV (Enhanced Needle Visualization)
- Color/CPA Mode Image Controls
- M-Mode Image Controls
- Spectral Doppler Mode Image Controls
- 2D Mode Image Controls
- 8 System Customization and Service
- Customizing Your System
- Configuring Security Policies
- Servicing your system
- Reinstalling Software
- Checking the Software Version
- Checking the System’s Serial Number
- Checking the Tablet’s Serial Number
- Checking the License Status
- Resetting User Settings
- Backing Up System Settings and Patient Data
- Restoring System Settings and Patient Data
- Resetting Your System
- Testing the System
- Exporting System Logs
- Reading the User Manual
- 9 Transducers
- 10 Transducer Care
- 11 System Maintenance
- 12 Appendix
99
eiinndeie
Customizing Your System
8
P6992-4, EN, 16/12/6
8
System Customization and Service
Customizing Your System
You can customize your system to streamline your workflow and increase efficiency Use the setup tools to
adjust sets of controls for defaults and other settings
On the system, touch Menu > Settings The setup tools are categorized into various sections Touch each
section to access the settings
General
Dock Control Panel at: Set the control panel at the left or right side of the screen
Enable freeze gesture: Enable double-tapping the screen to freeze the real-time scan
Language: Set the system language, and the system restarts automatically
Export Settings/Import Settings: Insert an external storage, touch Export/Import and select the storage
directory
Preset
Default preset/Preset list: Touch Edit, set the default preset and re-arrange the preset list on the Preset
screen, then touch Save (See Selecting a Preset on page 2)
Export preset/Import preset: Export/import customized presets to/from your external storage (See
Selecting a Preset on page 2)
Patient
Auto-create Patient Name and ID: Enable creating a set of patient name and ID every time you start a
new exam
Show Patient Information: If you want to protect patient privacy, disable this function to conceal
patient information during real-time scanning However, the system does not allow acquiring images/
loops without patient name
Show Study Information: If you want to protect physician privacy, disable this function to conceal
physician and institution information during real-time scanning
Patient Information Unit: Set the measurement unit for filling in patient information
Exam
Add logos and names for the institutions and physicians
Delete exams before: Set the number of weeks ago the exams are done, then touch Delete > OK
Workflow
Screen after Enter Ultrasound: Select the screen to enter after starting/logging in the system
Auto-freeze after Minutes: Set the number of minutes of waiting before the scan is frozen
automatically
Status after Freeze: Assign the first action to perform after freezing the scan