User's Manual
Table Of Contents
- 1 Read This First
- 2 Safety Information
- 3 Overview
- 4 Preparing the System
- Inserting a microSD Card
- Using the Stand
- Charging the System
- Connecting the Transducer
- Removing the Transducer
- Using the System On The Go
- Using the Wheel Brakes
- Placing the Transducer Holder
- Mounting the System to the System Cart
- Adjusting the System Cart Height
- Connecting an External Printer
- Tilting the System
- Unmounting the System From the System Cart
- Moving the System
- Outputting the System Display to an HDMI-Enabled TV or Monitor
- Supported External Printers
- 5 Using the System
- Turning On/Off the System
- Logging Into the System
- Launching the Main Screen
- Setting the System Time and Date
- Controlling the System
- Setting the System Language
- Identifying the Main Screen Layout
- Switching the Control Panel Pages
- Managing the System Power
- Managing Disk Space
- Network Configuration
- DICOM Configuration
- 6 Performing an Exam
- Starting a New Exam
- Adding a New Patient
- Loading a Worklist
- Selecting a Preset
- Setting the Transducer Orientation
- Selecting/Switching a Scan Mode
- Adjusting the Displayed Image
- Freezing an Image
- Adding Annotations
- Adding Measurements
- Saving and Printing the Image
- Reviewing the Image
- Exporting the Exam
- Managing the Exam List
- Ending the Exam
- 7 Using Image Controls
- 2D Mode Image Controls
- Overview
- Adjusting Gain
- Adjusting Frequency
- Adjusting Time Gain Compensation (TGC)
- Adjusting the Scan Depth
- Adjusting the Focus Depth, Focal Zone and Focal span
- Adjusting Dynamic Range
- Using Tissue Harmonic Imaging (THI)
- Adjusting Persistence
- Adjusting Sharpness and Smoothing
- Adjusting Gray Map
- Adjusting Chroma Map
- Adjusting Steer Angle
- Adjusting the Sector Width and Position
- Adjusting Power
- Using Trapezoidal Imaging
- Adjusting Density
- Using Compound Imaging
- Using ENV (Enhanced Needle Visualization)
- Color/CPA Mode Image Controls
- M-Mode Image Controls
- Spectral Doppler Mode Image Controls
- 2D Mode Image Controls
- 8 System Customization and Service
- Customizing Your System
- Configuring Security Policies
- Servicing your system
- Reinstalling Software
- Checking the Software Version
- Checking the System’s Serial Number
- Checking the Tablet’s Serial Number
- Checking the License Status
- Resetting User Settings
- Backing Up System Settings and Patient Data
- Restoring System Settings and Patient Data
- Resetting Your System
- Testing the System
- Exporting System Logs
- Reading the User Manual
- 9 Transducers
- 10 Transducer Care
- 11 System Maintenance
- 12 Appendix
InnoSight Ultrasound System
Managing Disk Space
inee
64
P6992-4, EN, 16/12/6
Battery Status Icons
The battery level is indicated by icons shown on the system toolbar
Battery status icon Meaning
The battery is fully charged
The battery is to 99 charged
The battery is 6 to 9 charged
The battery is 4 to 9 charged
The battery is 2 to 39 charged
The battery is critically low
The battery is charging
The battery cannot be identified
Battery temperature is too high or too low and the battery
stops charging
When the battery level reaches a critically low state, the system shuts down automatically
Sleep Mode
Sleep mode is a low-power mode that conserves battery power and allows quick startup of the system
It should be used only for short periods of time, such as when you transport the system between exam
locations
To enter/exit Sleep mode, press the Power button
If automatic logoff is enabled, the current user is logged off when the system enters Sleep mode
Managing Disk Space
Always beware of the amount of free space in the system storage If the disk space on the system drive is
full, the system cannot acquire images To check the system storage used, open the system tool menu and
watch the number of percentage next to Storage Usage
The system sends warning messages when its available disk space reaches any of the following level:
Low on disk space: The disk space available for storing images is low Delete some stored exams to
ensure that there will be enough room for new images
Critically low on disk space: The disk space available for storing images is critically low Immediately
delete some stored exams to free up your disk space
Disk Full: No disk space is available and no images can be saved You must delete stored exams in order
to have space for acquiring new images
To free up storage space, go to Menu > Settings > Exam, and delete stored exams in the appointed number
of weeks