User's Manual
Table Of Contents
- 1 Read This First
- 2 Safety Information
- 3 Overview
- 4 Preparing the System
- Inserting a microSD Card
- Using the Stand
- Charging the System
- Connecting the Transducer
- Removing the Transducer
- Using the System On The Go
- Using the Wheel Brakes
- Placing the Transducer Holder
- Mounting the System to the System Cart
- Adjusting the System Cart Height
- Connecting an External Printer
- Tilting the System
- Unmounting the System From the System Cart
- Moving the System
- Outputting the System Display to an HDMI-Enabled TV or Monitor
- Supported External Printers
- 5 Using the System
- Turning On/Off the System
- Logging Into the System
- Launching the Main Screen
- Setting the System Time and Date
- Controlling the System
- Setting the System Language
- Identifying the Main Screen Layout
- Switching the Control Panel Pages
- Managing the System Power
- Managing Disk Space
- Network Configuration
- DICOM Configuration
- 6 Performing an Exam
- Starting a New Exam
- Adding a New Patient
- Loading a Worklist
- Selecting a Preset
- Setting the Transducer Orientation
- Selecting/Switching a Scan Mode
- Adjusting the Displayed Image
- Freezing an Image
- Adding Annotations
- Adding Measurements
- Saving and Printing the Image
- Reviewing the Image
- Exporting the Exam
- Managing the Exam List
- Ending the Exam
- 7 Using Image Controls
- 2D Mode Image Controls
- Overview
- Adjusting Gain
- Adjusting Frequency
- Adjusting Time Gain Compensation (TGC)
- Adjusting the Scan Depth
- Adjusting the Focus Depth, Focal Zone and Focal span
- Adjusting Dynamic Range
- Using Tissue Harmonic Imaging (THI)
- Adjusting Persistence
- Adjusting Sharpness and Smoothing
- Adjusting Gray Map
- Adjusting Chroma Map
- Adjusting Steer Angle
- Adjusting the Sector Width and Position
- Adjusting Power
- Using Trapezoidal Imaging
- Adjusting Density
- Using Compound Imaging
- Using ENV (Enhanced Needle Visualization)
- Color/CPA Mode Image Controls
- M-Mode Image Controls
- Spectral Doppler Mode Image Controls
- 2D Mode Image Controls
- 8 System Customization and Service
- Customizing Your System
- Configuring Security Policies
- Servicing your system
- Reinstalling Software
- Checking the Software Version
- Checking the System’s Serial Number
- Checking the Tablet’s Serial Number
- Checking the License Status
- Resetting User Settings
- Backing Up System Settings and Patient Data
- Restoring System Settings and Patient Data
- Resetting Your System
- Testing the System
- Exporting System Logs
- Reading the User Manual
- 9 Transducers
- 10 Transducer Care
- 11 System Maintenance
- 12 Appendix
65
inee
Network Configuration
InnoSight Ultrasound System
P6992-4, EN, 16/12/6
Network Configuration
The system network is configured from the system tool menu (See page 61) The configuration
information for the system includes the IP address, port number, and other attributes required for
transmitting images and other study data across a network The system network must be configured before
you use either the standard network support or the capabilities available through the DICOM networking
options
Connecting the System to the Network by Ethernet
1 Connect one end of the provided network connection cable to the wall receptacle for your network
2 Connect the other end of the cable to the Ethernet socket on the system
3 On the imaging screen, open the system tools menu (See page 61)
4 Touch
to go to its settings
Check Ethernet
to enable the Ethernet function If your system does not use Dynamic Host
Configuration Protocol (DHCP) to specify the addresses of domain name servers, continue to the next
step
6 Touch Ethernet configuration Touch Static IP and configure the DNS settings
Consult your network administrator about the appropriate settings
Touch Save Touch
to leave the setting If the connection is successful, appears on the system
toolbar
Connecting the System to the Wireless Network
Wireless connection quality can be affected by many factors The system may experience a
connection interruption while a network job is in progress If this occurs, the job remains in the
job queue When the connection is restored, the system resumes the job automatically
The system supports the following wireless security standard: WEP, WPA/WPA2 and WPS It is
your responsibility to configure the wireless network security mechanisms that are compatible
with your network
1 Open the system tools menu (See page 61)
2 Touch
to enable the wireless network function, then touch and hold this button to go to its
settings
3 On the available network list, select an access point on an existing wireless network with your DICOM
server, and enter the required settings
Consult your network administrator about the appropriate settings
4 Touch
to leave the settings If the connection is successful, appears on the system toolbar
indicating the network strength