User's Manual
Table Of Contents
- 1 Read This First
- 2 Safety Information
- 3 Overview
- 4 Preparing the System
- Inserting a microSD Card
- Using the Stand
- Charging the System
- Connecting the Transducer
- Removing the Transducer
- Using the System On The Go
- Using the Wheel Brakes
- Placing the Transducer Holder
- Mounting the System to the System Cart
- Adjusting the System Cart Height
- Connecting an External Printer
- Tilting the System
- Unmounting the System From the System Cart
- Moving the System
- Outputting the System Display to an HDMI-Enabled TV or Monitor
- Supported External Printers
- 5 Using the System
- Turning On/Off the System
- Logging Into the System
- Launching the Main Screen
- Setting the System Time and Date
- Controlling the System
- Setting the System Language
- Identifying the Main Screen Layout
- Switching the Control Panel Pages
- Managing the System Power
- Managing Disk Space
- Network Configuration
- DICOM Configuration
- 6 Performing an Exam
- Starting a New Exam
- Adding a New Patient
- Loading a Worklist
- Selecting a Preset
- Setting the Transducer Orientation
- Selecting/Switching a Scan Mode
- Adjusting the Displayed Image
- Freezing an Image
- Adding Annotations
- Adding Measurements
- Saving and Printing the Image
- Reviewing the Image
- Exporting the Exam
- Managing the Exam List
- Ending the Exam
- 7 Using Image Controls
- 2D Mode Image Controls
- Overview
- Adjusting Gain
- Adjusting Frequency
- Adjusting Time Gain Compensation (TGC)
- Adjusting the Scan Depth
- Adjusting the Focus Depth, Focal Zone and Focal span
- Adjusting Dynamic Range
- Using Tissue Harmonic Imaging (THI)
- Adjusting Persistence
- Adjusting Sharpness and Smoothing
- Adjusting Gray Map
- Adjusting Chroma Map
- Adjusting Steer Angle
- Adjusting the Sector Width and Position
- Adjusting Power
- Using Trapezoidal Imaging
- Adjusting Density
- Using Compound Imaging
- Using ENV (Enhanced Needle Visualization)
- Color/CPA Mode Image Controls
- M-Mode Image Controls
- Spectral Doppler Mode Image Controls
- 2D Mode Image Controls
- 8 System Customization and Service
- Customizing Your System
- Configuring Security Policies
- Servicing your system
- Reinstalling Software
- Checking the Software Version
- Checking the System’s Serial Number
- Checking the Tablet’s Serial Number
- Checking the License Status
- Resetting User Settings
- Backing Up System Settings and Patient Data
- Restoring System Settings and Patient Data
- Resetting Your System
- Testing the System
- Exporting System Logs
- Reading the User Manual
- 9 Transducers
- 10 Transducer Care
- 11 System Maintenance
- 12 Appendix
91
inen
2D Mode Image Controls
InnoSight Ultrasound System
P6992-4, EN, 16/12/6
Adjusting Chroma Map
Adjust the chroma (color tone and saturation) value with different brightness
Touch Chroma +/- to adjust the tone
Adjusting Steer Angle
Optimize the viewing area by adjusting the steer angle This function works only with linear array
transducers
Touch Steer +/- to adjust the angle
Adjusting the Sector Width and Position
Adjust the ROI of the imaging area for image width and image position A smaller sector width increases the
frame rate
Touch Sector Width +/- to adjust the width Touch Sector Pos +/- to adjust the position
Adjusting Power
Adjust the acoustic output power value to the expected target
Touch Power +/- to adjust the value
Using Trapezoidal Imaging
Increase the range of view of the ultrasound image when using a linear transducer
Touch Trap to enable trapezoidal imaging
Adjusting Density
Adjust the density of the scan lines Higher density obtains better horizontal resolution with lower frame
rate, while lower density obtains higher frame rate
Touch Density repeatedly to select a desired line density
Using Compound Imaging
Reduce speckles and improve contrast resolution
Frequency compounding: Combine multiple images acquired from different frequencies Touch FQBeam
to enable frequency compounding
Spatial compounding: Combine multiple images acquired from different beam angles Touch SonoCT
repeatedly to enable and adjust spatial compounding
Using ENV (Enhanced Needle Visualization)
When performing a biopsy with the supported transducer, the system offers on-screen needle guides to
further enhance imaging of the needle Before using the ENV function, make sure the following conditions
are met:
2D mode is selected
An L12-4 transducer is connected to the system