4. MAINTAINABILITY & QUALITY
4.1 Maintainability
Module cannot be reworked.
Qisda will analyze failures and update report to customer by 8D format.
4.2 Quality Target
The quality target for the delivered quality (0 Km-line failures) is zero defects.
Quality target is complaint rate at delivery <50ppm.
5. E
NVIRONMENTAL
R
EQUIREMENTS
5.1 Operating and Storage Requirements
5.1.1 Temperature
Operating: - 40 to 90 °C
Storage: - 40 to 90 °C
5.1.2 Floor Life
Ambient Condition: 30 °C/60% RH
Maximum Floor time: 168 hour (MSL 3)
5.1.3 Shelf Life
When stored in a noncondensing atmospheric environment of < 40°C/90%
RH. (Moisture Barrier Bag)
6. H
ANDLING
R
EQUIREMENTS
Do not touch any pin of module while assembling.