User's Manual

14
Shortcut Operations
In standby, hold key for over 0.5 second to enter Dual Watch
mode. The radio will scan the channel in every 5 seconds. When the radio
receives matching signal, it pause scanning until the signaling disappear.
Repeat
above operation to exit Dual watch.
DUAL WATCH
FREQUENCY SCAN
CHANNEL/FREQUENCY SCAN
In VFO mode, this function is designed to monitor signal of every
communicative frequency point of "step size" you have set.
In VFO mode, press the Main Band
1.
key to enter channel scan.
During the scanning adjust the Main band selector knob or press
2.
microphone
[ UP/DOWN ] key will change the scan direction.
Press
3.
key to exit scan.
CHANNEL SCAN
In channel mode, press the Main Band
1.
key to enter channel scan.
During the scanning, adjust the Main band selector knob or press
2.
microphone [ UP/DOWN ] key will change the scan direction.
Press
3.
key to exit scan.
In channel mode, switch selector knob to choose the channel, then hold
In VFO mode, turn selector knob to select the desired frequency or
1.
input frequency by MIC's numeric keys.
Hold
2.
key until the transceiver prompt
DU and the display of channel number ashes.
Turn selector knob to select the channel number to store. (If the
3.
storage has data , the LCD will display the
frequency, otherwise will display"----------")
Press
4.
key, the LCD display MEN- IN, the channel edit completed.
In channel mode, turn the selector knob to choose the channel.
1.
Hold
2.
key until the transceiver prompt a Du and channel number
display ashes.
Turn selector knob to choose channel number for storage. ( If the
3.
CHANNEL SCAN SKIP
CHANNEL EDIT
CHANNEL COPY
6
EMERGENCY ALARM
To start emergency alarm, hold the right volume knob until the trans
-ceiver displays ALARM and emit alarm. Re-power on the transceiver to
exit alarm. This transceiver has 4 kind of alarm which can be setup by
programming software.
6
for over 0.5 second, the radio prompts
"DU DU", and LCD displays "SKIP", and now
the current channel is Scan Skip.
SCAN RANGE LIMIT
You can set the VFO scan frequency range by this function:
Choose upper limit and lower limit frequency, there are L1/U1- L5/
1.
U5, five couple of limit frequency for selection. L stands for lower
limit and U stands for the upper limit. the upper limit must over the
lower limit frequency. Please refer to the
Channel Edit to setup the limit frequency.
In VFO mode, set the VFO frequency in
2.
the range between upper and lower limit.
Press
3.
key to start scan in lmited range.