Product specifications

B–Assigning LUNs to the MPX200 for Data Migration
Assigning LUNs from an HDS Array
ISR654605-00 A B-7
6. Select the LUNs to be assigned to the DM-Host by checking the box
associated with the previously planned LUNs, as shown in Figure B-7.
Figure B-7 Selecting LUNs
7. To accept and save the LUN assignment, click OK.
8. Refresh the data migration user interface to see if the LUN assignment is
reflected properly, and that the appropriate array entity appears under FC
Array. (You may need to click the Refresh button several times to correctly
reflect the changes.)
Assigning LUNs from an HDS Array
To assign LUNs:
1. Perform zoning as follows:
a. Connect the Fibre Channel ports of the data migration appliance to a
switch where the storage controller ports are also logged.
b. Using switch management tools, create a zone, DM_Host_HDS.
c. In this zone, add the WWPN of the data migration appliance Fibre
Channel ports and storage controller ports.
d. Save the zoning information and activate the new zoning configuration.
2. Open the Storage Navigator Modular application. If you are using the tool for
the first time, you may have to discover the array using the IP assigned to
the storage controller.
3. On the Tool menu, click Operation Mode > Change, and then change to
Management Mode.
Storage Vendor HDS
Array Model
AMS/WMS series arrays
LUN Assignment Tool
Storage Navigator Modular user interface