User`s guide
12 – Troubleshooting
Troubleshooting Problems and Solutions
FS0054603-00 C   12-9
Q
Unable to run update 
flash BIOS
Cause: This feature is not supported for all operating systems.
Solution: The Update Flash utility is available only for 
Windows 2000/Windows Server 2003 and Red Hat/SuSE Linux.
Unable to run the 
loopback test
Cause: A loopback connector was not attached to the Fibre 
Channel connector on the HBA.
Solution: A loopback connector must be attached to the Fibre 
Channel connector on the HBA. The NVRAM extended firmware 
setting Connection Options must be set to 0—Loop Only. See 
section 10.1.2.2 for details.
Unable to run the 
read/write buffer test
Cause: The device does not support SCSI Read/Write Buffer 
commands.
Solution: Not all devices support the SCSI Read/Write Buffer 
commands. The read/write buffer test reports Unsupported if the 
device does not support these commands.
Current Path dialog 
box does not display 
my saved configuration
Cause: The saved configuration is not detected by the qlremote 
agent.
Solution: The Current Path dialog box displays the current 
configuration detected by the qlremote agent. Click the Refresh 
button to force a manual refresh. Verify that the configuration 
saved is the current configuration. This includes the following: 
no device was removed, and the HBA tree displays the 
appropriate device port name and LUN information. 
Current Path dialog 
box does not display 
my storage device port 
names and LUNs
Cause: The qlremote agent is unable to detect or communicate 
with the devices.
Solution: Verify that the devices are online and operational. 
Verify that the operating system driver detects and 
communicates with the devices. Click the Refresh button to 
force a manual refresh. Verify that the HBA tree displays the 
appropriate device port name and LUN information.
When I change the 
current path in the 
Current Path dialog 
box, the HBA tree does 
not update
Cause: The qlremote agent is unable to detect or communicate 
with the devices.
Solution: 
■ Verify that the devices are online and operational. Verify that 
the operating system driver detects and communicates with 
the devices. Click the Refresh button to force a manual 
refresh. Verify that the HBA tree displays the appropriate 
device port name and LUN information.
■ The DNS or the local host file may contain an incorrect IP 
address for the host name. Use the Ping command to ping 
the host name; verify that the correct IP address is translated 
from the name.
Table 12-1. Troubleshooting Problems and Solutions (Continued)
Problem Cause and Solution