Installation guide
146
EMC Host Connectivity with QLogic Fibre Channel HBAs and CNAs in the Windows Environment
Miscellaneous Planning and Procedures
◆ After CHAP settings are made, click OK at the bottom of the 
Authentication Configuration dialog, as shown in Figure 121 on 
page 144. 
◆ To save all target settings, click Save at the bottom of the 
SANsurfer iSCSI HBA Manager, Target Settings tab, as shown 
in Figure 119 on page 143. You will be prompted for the 
SANsurfer security password. The default password is 
config, 
but it can be changed.
◆ After the settings are saved, SANsurfer resets the adapter, and if 
target information was discovered properly, you will see active 
connections listed on the SANsurfer iSCSI HBA Manager, Target 
Information tab. You can also view active targets under the 
adapter in the left pane as shown in Figure 122.
Figure 122 SANsurfer iSCSI HBA Manager, Information tab
SANsurfer has other features that are useful in managing your iSCSI 
storage configuration. Please refer to the QLogic SANsurfer docu-
mentation for more information about these additional features.