Installation guide
172
EMC Host Connectivity with QLogic Fibre Channel HBAs and CNAs in the Windows Environment
Miscellaneous Planning and Procedures
Procedure for replacing a QLogic adapter in Stratus ftServers 
without rebooting
This section contains the following information:
◆ “EMC VNX series or CLARiiON storage systems”, next
◆ “EMC Symmetrix arrays with device masking enabled” on 
page 172
EMC VNX series or CLARiiON storage systems
Use of this procedure requires NAVICLI installed on the host system.
1. Remove the IO slice that contains the defective QLogic adapter.
2. Replace the defective adapter with a new adapter of same Stratus 
part number (that is, U525 or U526). The adapter should be 
inserted into the same PCI slot from which the defective adapter 
was removed. (Inserting the replacement adapter into another 
PCI slot requires a driver to be loaded for the adapter.)
3. Reinsert IO slice with the new adapter, and reconnect all cables.
4. Power up the ftServer, and let the IO Slice come online and 
duplex, as shown in the Stratus ftServer Management tool.
5. Change the FC switch zoning to add the WWN of the replaced 
adapter to the appropriate zones.
6. Restart the Unisphere/Navisphere Agent using the Service 
Control Manager applet.
7. In the Unisphere/Navisphere Manager, use connectivity status to 
verify the new adapter is present and logged in. Alternately, use 
the port ‘list’ command in navicli.
8. Using navicli, connect the adapter to the storage group with the 
following command: 
navicli –h 
<Clariion IP Addr>
 storagegroup –connecthost 
–host 
<host-name>
 -gname 
<Storage-group-name>
This command will give the user the following prompt:
Connect host <host-name>to storage group 
<Storage-group-name> (y/n)?