Owner's manual

Read Carefully This instruction sheet contains vital informa-
tion for the proper installation, use, and efficient operation of the
heater described. Carefully read this manual before installa-
tion, cleaning, or operation of the heater. Failure to adhere to
the instructions could result in fire, electrical shock, death, seri-
ous personal injury, or property damage. Save these instruc-
tions and review frequently for continuing safe operation and
instructing future users.
CAUTION TO REDUCE RISK OF FIRE AND ELEC-
TRIC SHOCK:
1. Disconnect all power coming to the heater at main service
panel before wiring, installing elements, servicing, or disas-
sembling heater.
2. All wiring must be in accordance with local and National
Electrical Codes and the heater must be grounded as a pre-
caution against possible electrical shock.
3. Verify the power supply voltage coming to the heater match-
es the rating printed on the elements before energizing.
4. Supply wire coming to the heater must be rated at least 90
degrees C. USE COPPER WIRE ONLY.
5.Minimum clearances, as specified in Figure 1, must be main-
tained. Keep combustible material, such as boxes, crates,
etc., away from heater.
6. This heater is not suitable for use in hazardous locations as
described by the NFPA. Do not use in areas where paint,
gasoline, or other flammable liquids are used or stored.
7. Do not use TYPE RP heaters in areas where corrosive
agents are present, such as marine, green houses, or chem-
ical storage areas. TYPE RS heaters are better suited for
these applications.
8. The mounting structure and anchoring hardware must be
capable of reliably supporting the total weight of the heater
and all accessories used. See selection chart for heater
weight.
9. This heater is intended for ceiling mounting (or wall mount-
ing, with accessory –WMB Wall Mounting Bracket) only.
Elements must be horizontal.
F
IXTURE SELECTION CHART
( Enclosure only - Select Appropriate Element from Element Selection Chart )
Type RP3 & RS3
3 Element
Infrared Heaters
Installation Instructions
WARNING
!
SAVE THESE INSTRUCTIONS
REFLECTOR DESIGN DIMENSIONS
3
0 DEG. 60 DEG. 90 DEG. HEIGHT WIDTH LENGTH WT.
E
NCLOSURE SYMMETRICAL ASYMMETRICAL SYMMETRICAL ASYMMETRICAL SYMMETRICAL in. (mm) in. (mm) in. (mm) lbs. (kg)
PAINTED STEEL RP323SA RP323ASA RP326SA RP326ASA RP329SA
2
4 (610) 19 (8.6)
S
TAINLESS STEEL RS323SA RS323ASA RS326SA RS326ASA RS329SA
PAINTED STEEL RP333SA RP333ASA RP336SA RP336ASA RP339SA
7
.125 (181) 21.5 (546)
33 (838) 24 (10.9)
STAINLESS STEEL RS333SA RS333ASA RS336SA RS336ASA RS339SA
PAINTED STEEL RP343SA RP343ASA RP346SA RP346ASA RP349SA
46 (1168) 31 (14.1)
STAINLESS STEEL RS343SA RS343ASA RS346SA RS346ASA RS349SA