KS212C User Manual KS212C – 3600 watt K Cardioid Sub TD-001536-01-A *TD-001536-01* ®
EXPLANATION OF SYMBOLS The term “WARNING!” indicates instructions regarding personal safety. If the instructions are not followed the result may be bodily injury or death. The term “CAUTION!” indicates instructions regarding possible damage to physical equipment. If these instructions are not followed, it may result in damage to the equipment that may not be covered under the warranty. The term “IMPORTANT!” indicates instructions or information that are vital to the successful completion of the procedure.
15. Adhere to all applicable, local codes. 16. To prevent electrical shock, the power cord shall be connected to a mains socket outlet with a protective earthing connection. 17. Consult a licensed, professional engineer when any doubt or questions arise regarding a physical equipment installation. 18. Do not use any aerosol spray, cleaner, disinfectant or fumigant on, near or into the apparatus. Clean only with a dry cloth. 19. Do not unplug the unit by pulling on the cord, use the plug. 20.
RoHS Statements These products are in compliance with European Directive 2011/65/EU – Restriction of Hazardous Substances (RoHS). These products are in compliance with “China RoHS” directives per GB/T26572.
KS212C Features 1 Top 1 2 Bottom Horizontal Top 7 7 3 4 8 9 5 6 Front Horizontal Bottom Rear 3 11 10 — Figure 1 — 1. Rubber-feet stacking-alignment cups 6. Slip-resistant feet - four on the side 2. Four low-noise, heavy-duty casters 7. Cast aluminum handles 3. Amplifier protection rails – protects the amplifier when the unit is rolled off, for example, a curb. 8. M20 threaded socket for 35 mm speaker pole 9. 18 mm birch plywood 4. M20 threaded socket for 35 mm speaker pole 10.
About the KS212C Cardioid Subwoofer The term Cardioid refers to the heart-shaped coverage pattern of an audio device. A cardioid microphone is designed to be most sensitive at the front (on-axis), and least sensitive at the rear (180 degrees off-axis). A Cardioid Subwoofer operates exactly the same way, and is loudest at the front and quietest at the rear.
Applications and Installation WARNING!: Before placing, installing or mounting any speaker product, inspect all hardware, cabinets, transducers, brackets and associated equipment for damage. Any missing, corroded, deformed, or non-load rated component could significantly reduce the strength of the installation or placement. Any such condition severely reduces the safety of the installation and should be immediately corrected.
Pole-mounting Loudspeakers Over the KS212C The KS212C is equipped with two 35 mm M20 pole sockets, one on the top, and one on the side for polemounting a loudspeaker over the unit. Figure 5 shows a KS212C in a vertical orientation with a K.2 Series loudspeaker mounted above. Figure 6 shows a KS212C in a horizontal orientation with a K.2 Series loudspeaker mounted above. Use the table below to determine which poles you can use with the various K and K.
AC Mains Refer to Figure 7 AC Mains Disconnection Push in on the bottom of the power switch to turn the amplifier off. Unplug the AC cable from the power source. To remove the AC mains cord from the amplifier, grasp the IEC connector’s plastic body, press the yellow latch release button and pull. Do not pull the plug out using the cord. Powering up Your KS212C Connect the AC power cord to the IEC socket on the back of the amplifier.
3. Turn on the KS212C, 4. Turn on the “top-boxes”. 5. The level controls on your mixer may now be brought up. Power Off Sequence: 1. Turn off “top boxes.” 2. Turn off the KS212C 3. Turn off all audio source devices. NOTE: If a KS212C speaker is being driven from the output of another KS212C unit, it should be turned on after the unit feeding it signal, and turned off before the unit feeding it signal.
Inputs and Outputs 1 2 The KS212C amplifier has two separate female combination XLR / 1/4” Phone Jack inputs, and two corresponding pre‑gain pass-through male XLR outputs. PUSH PUSH Refer to Figure 9 1. SIG LED – When illuminated (green), it indicates a signal is present for Input A and/or B. If this LED is not illuminated, the input signal is missing or too low to detect. 3 2. IN A/B – Combination XLR – 1/4” Phone Jack connector. Balanced XLR and 1/4” input.
KS212C Menu The KS212C loudspeakers provide a multi-function digital display for control and selection of loudspeaker functions including scenes, crossover, and delay. Display Introduction 1 1. Home Screen – Displays the equipment model and the main functionality headings. Light background with black text indicates the item is selected. 2. Exit, or go back button – press to return to the previous screen or menu level. 3. Enter button – confirm a selected parameter or open the selected menu item. 4.
Menu Listing CROSSOVER Select the CROSSOVER setting 80 Hz – applies a 80 Hz low-pass filter. 80 Hz is optimized for the K.2 Series and future loudspeakers 100 Hz – applies a 100 Hz low-pass filter. 100 Hz is optimized for the legacy K, KLA, and KW loudspeakers CROSSOVERS 80 Hz 100 Hz CROSSOVERS Both of the crossover frequencies are time-aligned with the K.2 Series when the K.2 loudspeaker is pole-mounted over the KS212C and the front edges of the KS212C and K.2 Series loudspeakers are parallel.
33.4 in 847.5 mm 33.4 in 847.5 mm Dimensions 15.3 in 389 mm 24.6 in 624.5 mm Front View 15.3 in 389 mm 15.3 in 389 mm 24.6 in 624.5 mm 24.6 in 624.
KS212C Specifications Configuration Dual 6th-Order Bandpass Cardioid Subwoofer LF Transducer 2 x 12-inch (305 mm), Cone Frequency Response with EQ (-6 dB) 44 - 104 Hz Frequency Range with EQ (-10 dB) 39 - 118 Hz Nominal Coverage Angle 180˚ Cardioid (15 dB rear rejection @ 70 Hz) Maximum SPL 132 dB @ 1 m (peak) Amplifier Class D 2 x 1800 W (peak) Cooling Low-Noise, Variable Speed Fan Controls Power On/Off Gain Control Rotary Encoder 2 x Selection Buttons Indicators 2 x Power LED (front and
® Mailing Address: QSC, LLC 1675 MacArthur Boulevard Costa Mesa, CA 92626-1468 USA Telephone Numbers: Main Number: 1.714.754.6175 Sales & Marketing: 1.714.957.7100 Toll free (USA only) 1.800.854.4079 Customer Service: 1.714.957.7150 Toll free (USA only) 1.800.772.2834 Facsimile Numbers: Sales & Marketing FAX: 1.714.754.6174 Customer Service FAX: 1.714.754.6173 World Wide Web: qsc.com E-mail: info@qsc.com service@qsc.