Owner's Manual

35
TD-000472-00-A
Output Channel
EQ
The Main LR and Aux 1 – 6 outputs have a 1/3 octave graphic EQ. Stereo auxes 7/8 and 9/10 use a parametric EQ similar to the input channel’s EQ.
Home Select the
Aux Bank
Touch a
Select Button
Select
EQ Tab
EQ
Aux Outputs
Aux 1
or
Main
1.
EQ Tab
– Selects the EQ screen
For Aux 1-6 and Main L/R
2.
Band Selector Buttons
– Touch a band to access faders.
3.
GEQ Graph
– Graphic representation of the equalizer settings. The
currently selected group of frequencies has a blue background.
4.
Center Frequency Labels
– Indicates the center frequency of a
frequency band.
5.
EQ Faders
– Adjusts the audio level at the indicated frequency. Yellow
background indicates the fader is selected.
For all Output Channels
6.
Reset Button
– Sets all EQ controls to factory default.
7.
EQ In Button
– Engages the Graphic or Parametric EQ.
For Aux 7/8 & 9/10
8.
Parametric EQ Graph
– A graphic representation of the equalization
curve based on the EQ settings. When the EQ is engaged, the trace
changes from black to white.
Vertical Scale
– Represents audio level from 20 to +20 dB.
Horizontal Scale
– Represents frequency from 20 Hz to 20 kHz.
9.
Low and High Cut Buttons
– Engages/disengages the fi lters. These fi lters
cut frequencies below or above the frequency set by the corresponding Freq
control.
10.
Low and High Shelf Buttons
– Changes EQ Band 1 and Band 4 from
parametric fi lters to shelving fi lters and back. When a shelf fi lter is engaged,
the Bandwidth control is not available.
11.
Frequency Bands 1, 2, 3, and 4 Buttons
– Engages / disengages
the associated parametric EQ band. Four overlapping frequency ranges,
each adjustable from 20 Hz to 20 kHz. Each band has an associated Gain,
Frequency, and Bandwidth control.
12.
Freq Control Knobs
(Low and High Cut) – Sets the frequency of the low
and/or high cut fi lter as measured from a point 3 dB below 0 or unity.
13.
Gain Control Knobs
– Adjusts the gain at the frequency setting of the
associated EQ band. Range of -15 dB to +15 dB.
14.
Freq Control Knobs
(Frequency bands 1 – 4) – Sets the center frequency of the associated EQ band. If the Shelving fi lter is engaged, the Freq
control sets the frequency of the shelf fi lter at a point 3 dB above or below 0 or unity.
15.
Bandwidth Knobs
– Adjusts the bandwidth of the associated EQ band. The Bandwidth is measured in Q.
16.
Simple Button
– Hides the Low Cut, High Cut, Frequency, and BW controls. Does not effect existing settings.
— Figure 29 —
3
1
4
5
6
2
7
— Figure 30 —
8
9
10
11
12
13 14 15 16
7
6