Manual
+7(495) 797-3311 www.qtech.ru 
Москва, Новозаводская ул., 18, стр. 1 
106 
12.3 EFM OAM Example 
Example: 
CE and PE devices with point-to-point  link  enable  EFM  OAM  to  monitor  “the  First  Mile”  link 
performance. It will report the log information to network management system when occurring 
fault event and use remote loopback function to detect the link in necessary instance 
CE
PE
802.1ah OAMPDU
Ethernet 
1/1
Ethernet 
1/1
Typical OAM application topology 
Configuration procedure: (Omitting SNMP and Log configuration in the following) 
Configuration on CE: 
CE(config)#interface ethernet1/1 
CE (config-if-ethernet1/1)#ethernet-oam mode passive 
CE (config-if-ethernet1/1)#ethernet-oam 
CE (config-if-ethernet1/1)#ethernet-oam remote-loopback supported 
Other parameters use the default configuration. 
Configuration on PE: 
PE(config)#interface ethernet 1/1 
PE (config-if-ethernet1/1)#ethernet-oam 
Other parameters use the default configuration. 
Execute the following command when using remote loopback. 
PE(config-if-ethernet1/1)#ethernet-oam remote-loopback 
high 
ethernet-oam errored-frame threshold high 
{high-frames | none} 
no ethernet-oam errored-frame threshold high 
Configure the high threshold of errored 
frame event, no command restores the 
default value. (optional) 
ethernet-oam errored-frame-seconds threshold 
high {high-frame-seconds | none} 
no ethernet-oam errored-frame-seconds 
threshold high 
Configure the high threshold of errored 
frame  seconds  event,  no  command 
restores the default value. (optional) 