3.  Compatibility verification 
Compatibility verification is used to analyze whether the environment of the module accords 
the  data  manual  or  it  is  compatible  with  the  corresponding  standard,  because  the  module 
capability is able to be ensured only in the compatible environment. Sometimes, environment 
parameters exceed the data manual or the corresponding standard, it will make the falling of 
the module capability that result in the transmission error.  
Environment is not compatible with the module are as below: 
(1) Voltage exceeds the set range 
(2) Rx power is overload or is under the sensitivity of the transceiver 
(3) Temperature exceeds the range of the running temperature 
14.1.2 DDM Function 
DDM descriptions are shown in the following: 
1.  Show the monitoring information of the transceiver 
Administrator  is  able  to know  the  current  working  state  of  the  transceiver  and  find  some 
potential problems through checking the real-time parameters (including TX power, RX power, 
Temperature, Voltage, Bias current) and querying the monitoring information (such as warning, 
alarm, real-time state and threshold, and so on). Besides, checking the fault information of the 
fiber module helps administrator to fast locate the link fault and saves the restored time. 
2.  Threshold defined by the user 
For real-time parameters (TX power, RX power, Temperature, Voltage, Bias current), there are 
fixed thresholds. Because the user’s environments are difference, the users  is able to define 
the  threshold  (including high  alarm,  low  alarm,  high  warn,  low  warn)  to  flexibly  monitor  the 
working state of the transceiver and find the fault directly.  
The thresholds configured by the user and the manufacturer can be shown at the same time. 
When the threshold defined by the user is irrational, it will prompt the user and automatically 
process alarm  or  warning  according  to  the default threshold. (the user is able  to  restore all 
thresholds to the default thresholds or restore a threshold to the default threshold)  
Threshold  rationality: high/low warn  should be  between high  alarm  and  low  alarm and  high 
threshold should be higher than low threshold, namely, high alarm>= high warn>= low warn>= 
low alarm. 
For fiber module, verification mode of the receiving power includes inner verification and outer 
verification which are decided by the manufacturer. Besides the verification mode of the real-
time parameters and the default thresholds are same. 
3.  Transceiver monitoring 
Besides checking the real-time working state of the transceiver, the user needs to monitor the 
detailed status,  such as  the  former  abnormity time  and  the  abnormity type.  Transceiver 
monitoring helps  the user  to find  the former abnormity  status  through checking the  log and 