Manual
+7(495) 797-3311 www.qtech.ru 
Москва, Новозаводская ул., 18, стр. 1 
117 
Switch(config-if-ethernet1/21)#transceiver  threshold  tx-power  low-
warning -12 
Switch(config-if-ethernet1/21)#transceiver  threshold  tx-power  low-
alarm -10.00 
Step3: Show the detailed DDM information of the fiber module. The alarm uses the threshold 
configured by  the  user, the threshold configured by the  manufacturer is  labeled  with  the 
bracket. There is the alarm with ‘A-’ due to -13.01 is less than -12.00. 
Switch#show transceiver interface ethernet 1/21 detail 
Ethernet 1/21 transceiver detail information: 
Base information: 
…… 
Brief alarm information: 
RX loss of signal 
Voltage high 
RX power low 
TX power low 
Detail diagnostic and threshold information: 
 Diagnostic Threshold  
 Realtime Value High Alarm Low Alarm High Warn Low Warn 
 -------------- ----------- ----------- ---------- --------- 
Temperature(°C) 33 70 0 70 0 
Voltage(V) 7.31(A+) 5.00 0.00 5.00 0.00 
Bias current(mA) 6.11(W+) 10.30 0.00 5.00 0.00 
RX Power(dBM) -30.54(A-) 9.00 -25.00 9.00 -25.00 
TX Power(dBM) -13.01(A-) 9.00 -12.00(-25.00) 9.00 -10.00(-25.00) 
Example3: 
Ethernet 21 is inserted the fiber module with DDM. Enable the transceiver monitoring of the 
port after showing the transceiver monitoring of the fiber module.  
Step1: Show the transceiver monitoring of the fiber module. Both ethernet 21 and ethernet 22 
do not enable the transceiver monitoring, its interval is set to 30 minutes.  
Switch(config)#show  transceiver  threshold-violation  interface 
ethernet 1/21-22 
Ethernet 1/21 transceiver threshold-violation information: 
Transceiver  monitor  is  disabled.  Monitor  interval  is  set  to  30 
minutes. 
The last threshold-violation doesn’t exist. 