response, the no command restores the default setting. 
dot1x re-authentication 
no dot1x re-authentication 
Enables periodical supplicant authentication; the no 
command disables this function. 
dot1x timeout quiet-period 
<seconds> 
no dot1x timeout quiet-period 
Sets time to keep silent on port authentication failure; the no 
command restores the default value. 
dot1x timeout re-authperiod 
<seconds> 
no dot1x timeout re-
authperiod 
Sets the supplicant re-authentication interval; the no 
command restores the default setting. 
dot1x timeout tx-period 
<seconds> 
no dot1x timeout tx-period 
Sets the interval for the supplicant to re-transmit EAP 
request/identity frame; the no command restores the default 
setting. 
dot1x re-authenticate 
[interface <interface-name> ] 
Enables IEEE 802.1x re-authentication (no wait timeout 
requires) for all ports or a specified port. 
40.3 802.1x Application Example 
40.3.1 Examples of Guest Vlan Applications 
The Network Topology of Guest VLAN 
Notes: in the figures in this session, E2 means Ethernet 1/2, E3 means Ethernet 1/3 and E6 
means Ethernet 1/6. 
As showed in the next figure, a switch accesses the network using 802.1x authentication, with 
a  RADIUS  server  as  its  authentication  server.  Ethernet1/2,  the port  through  which the  user 
Internet 
SWITCH 
Ethernet1/2 
VLAN100 
Ethernet1/3 
VLAN10 
VLAN2 
Update server 
Authenticator server 
Ethernet1/6 
VLAN5 
User 