Manual
+7(495) 797-3311 www.qtech.ru 
Москва, Новозаводская ул., 18, стр. 1 
461 
2.  Globally set the max output power 
3.  Globally set the power management mode 
4.  Globally set non-standard PD detection mode 
5.  Globally  enable  or  disable  the  allowed  high-inrush  current  when  nonstandard  PD  is 
powered instantaneously 
6.  Enable or disable PoE on specified ports 
Command 
Explanation 
Global Mode 
power inline max <max-wattage> 
no power inline max 
Globally set the max output power of PoE. 
Command 
Explanation 
Global Mode 
power inline police enable 
no power inline police enable 
Enable/disable  the  power  priority 
management  policy  mode.  Disable  the 
power  priority  management  policy  mode  is 
not supported by switch. 
Command 
Explanation 
Global Mode 
power inline legacy enable 
no power inline legacy enable 
Set whether or not to provide power for non-
standard IEEE PD. Do not provide power for 
non-standard IEEE PD in switch. 
Command 
Explanation 
Global Mode 
power inline high-inrush enable 
no power inline high-inrush enable 
Enable/disable  the  allowed  high-inrush 
current when nonstandard PD is  powered 
instantaneously. 
Command 
Explanation 
Port Mode 
power inline enable 
Enable/ disable PoE. 