Manual
+7(495) 797-3311 www.qtech.ru 
Москва, Новозаводская ул., 18, стр. 1 
320 
34.3.2 ULPP Typical Example2 
ULPP typical example2 
ULPP  can  implement  the  VLAN-based  load  balance.  As  the  picture  illustrated,  SwitchA 
configures two ULPP groups: port E1/0/1 is the master port and port 1/0/2 is the slave port in 
group1, port 1/0/2 is the master port and port 1/0/1 is the slave port in group2. The VLANs 
protected by group1 are 1-100 and by group2 are 101-200.  Here both port E1/0/1 and port 
E1/0/2 at the forwarding state, the master port and the slave port mutually backup, respectively 
forward the packets of different VLAN ranges. When port E1/0/1 has the problem, the traffic of 
VLAN 1-200 are forwarded by port E1/0/2. When port E1/0/1 is recovering the normal state, 
still port E1/0/2 forwards the data of VLAN 101-200, the data of VLAN 1-100 are switched to 
port E1/0/1 to forward. 
SwitchA configuration task list: 
Switch(Config)#spanning-tree mst configuration 
Switch(Config-Mstp-Region)#instance 1 vlan 1-100 
Switch(Config-Mstp-Region)#instance 2 vlan 101-200 
Switch(Config-Mstp-Region)#exit 
Switch(Config)#ulpp group 1 
Switch(ulpp-group-1)#protect vlan-reference-instance 1 
Switch(ulpp-group-1)#preemption mode 
Switch(ulpp-group-1)#exit 
Switch(Config)#ulpp group 2 
Switch(ulpp-group-2)#protect vlan-reference-instance 2 
Switch(ulpp-group-1)#preemption mode 
Switch(ulpp-group-2)#exit 
Switch(Config)#interface ethernet 1/0/1 
Switch(config-If-Ethernet1/0/1)#switchport mode trunk 
SwitchB 
E1/0/1 
SwitchD 
SwitchA 
E1/0/2 SwitchC 
E1/0/2 
E1/0/
1 
Vlan  1-
100 
Vlan  101-
200 