Manual
+7(495) 797-3311 www.qtech.ru 
Москва, Новозаводская ул., 18, стр. 1 
49 
4. Enable EFM OAM loopback of port 
8.3 EFM OAM Example 
Example: 
CE and PE devices with point-to-point  link  enable  EFM  OAM  to  monitor  “the  First  Mile”  link 
performance. It will report the log information to network management system when occurring 
fault event and use remote loopback function to detect the link in necessary instance  
CE
PE
802.1ah OAMPDU
Ethernet 
1/0/1
Ethernet 
1/0/1
Typical OAM application topology 
Configuration procedure: (Omitting SNMP and Log configuration in the following) 
Configuration on CE: 
CE(config)#interface ethernet 1/0/1 
CE (config-if-ethernet1/0/1)#ethernet-oam mode passive 
CE (config-if-ethernet1/0/1)#ethernet-oam 
ethernet-oam errored-frame threshold high 
{high-frames | none} 
no ethernet-oam errored-frame threshold high 
Configure the high threshold of errored 
frame event, no command restores the 
default value. (optional) 
ethernet-oam errored-frame-seconds threshold 
high {high-frame-seconds | none} 
no ethernet-oam errored-frame-seconds 
threshold high 
Configure the high threshold of errored 
frame  seconds  event,  no  command 
restores the default value. (optional) 
Command 
Explanation 
Port mode 
ethernet-oam remote-loopback 
no ethernet-oam remote-loopback 
Enable  remote  EFM  OAM  entity  to 
enter  OAM  loopback  mode  (its  peer 
needs  to  configure  OAM  loopback 
supporting),  no  command  cancels 
remote OAM loopback. 
ethernet-oam remote-loopback supported 
no ethernet-oam remote-loopback supported 
Enable  remote  loopback  supporting  of 
port,  no  command  cancels  remote 
loopback supporting of port. 