DLP-515
Page 1 of 2
ASSIGN RECEIVER ADDRESS
Summary: This procedure assigns a unique identifying address to the receiver that allows proper
communication with the MICRO Manager through the NMCS.
Note: This procedure uses the MICRO Manager Software loaded on a PC to
communicate with the receiver through the NMCS.
1. Using a small flat-blade screwdriver, rotate the ADDRESS switch at the back of the
receiver as shown in Figure 515-1, to the desired address. The switch is labeled with the
numbers 0 through 9, and the letters A through F. This provides 16 unique addresses
from which to choose. No two receivers on a given daisy chain can have the same
address.
2. From the MICRO Manager Software, Log On to the system.
3. Use the MICRO Manager Software to address the NMCS and the receiver.
4. Disconnect one Optical Input on the receiver and verify that the disconnected channel
was reported to the MICRO.
5. Does the MICRO Manager Software communicate properly with the receiver?
If YES, connect the Optical cable and then go to step 6.
If NO, verify that the address switch is properly set and that the proper receiver was
being communicated with from the MICRO. Repeat steps 2, 3, and 4. If the problem still
exists, contact C-COR.net for assistance.
6. Update office records as required.
Stop! You have completed this procedure.