Castile Pellet Insert
C. Pellet Venting Charts
Figure 14.1
Fire Risk.
Only LISTED venting components may be
used.
NO OTHER vent components may be used.
Substitute or damaged vent components may
impair safe operation.
WARNING
The maximum horizontal venting allowed with no vertical vent-
ing attached is 48 inches (1219mm) including one 90° elbow
or two 45° elbows. This is our recommended horizontal vent-
ing installation. Addition of any horizontal venting beyond
48 inches (1219mm) Hearth & Home Technologies strongly
recommends a minimum of 60 inches (1524mm) of additional
vertical vent. Horizontal sections of vent pipe should have a
1/4 inch (6.35mm) rise per foot.
Hearth & Home Technologies recommends any installation
requiring more than two 90° elbows, or more than 15 feet
(4.5m) of venting to use 4 inch (102mm) vent.
NOTICE: These are guidelines for successful venting of your pellet appliance. The more vertical rise you can obtain in
your system, the better it will perform. Horizontal vent runs can accumulate ash and will need to be cleaned more often.
Try to keep them as short as possible.
ONE 90º ELBOW
Total
Horizontal
Minimum
Vertical
Vent
Diameter
403
553
663
773
884
994
10 10 4
11 11 4
12 12 4
13 13 4
14 14 4
15 15 4
16 16 4
17 17 4
18 18 4
19 19 4
TWO 90º ELBOWS
Total Minimum Vent
Horizontal Vertical Diameter
253
363
473
583
693
7104
8114
9124
10 13 4
11 14 4
12 15 4
13 16 4
14 17 4
15 18 4
THREE 90º ELBOWS
Total Minimum Vent
Horizontal Vertical Diameter
2114
3124
4134
5144
6154
7164
8174
9184
10 19 4
11 20 4
Figure 14.2
Figure 14.3
45° elbow is equivalent to 1 foot of straight pipe
90° elbow is equivalent to 3 feet of straight pipe
Minimum Vertical Vent for One Elbow
0
5
10
15
20
0 5 10 15 20
Horizontal Run, (ft)
Minimum Vertical Rise
(ft)
Minimum Vertical Vent for Two Elbows
0
5
10
15
20
0 5 10 15
Minimum Vertical
Rise, (ft)
Minimum Vertical Vent for Three Elbows
0
5
10
15
20
25
024681012
Length of Horizontal Sections (ft)
Minimum Vertical Rise
(ft)
Minimum Vertical Vent for One Elbow
Minimum Vertical Vent for Two Elbows
Minimum Vertical Vent for Three Elbows
Horizontal Run (FT)
Length of Horizontal Sections (FT)