Owner`s manual

R
November 5, 2014
7014-188G
Page 35
1200-I Pellet Insert
7. Cleaning Heat Exchanger Chambers & Drop Tube
• Frequency: Weekly or every 1 ton of fuel
• By: Homeowner
The amount of ash buildup in the repot will be a good
guide to determine how often you should clean the heat
exchangers.
a. Allow the appliance to completely cool down before
pulling the cleaning rods. Turn the thermostat on and
then immediately off to start the exhaust blower on its
cycle time. It will pull y ash out the exhaust instead
of into the room.
b. To access the cleaning rods lift the hopper lid. Both
black bent handle pull rods are located close to the
face of the appliance to the left and right side.
c. To clean, pull the rods straight out until it stops,
approximately 20 inches (508mm). Slide the rods
OUT and IN a couple of times.
WARNING
Heat exchanger cleaning rods may be warm
to the touch. For safety purposes wear
gloves.
Do not pull heat exchanger cleaning rods
while appliance is operating.
Push cleaning rods IN when done, DO NOT
leave cleaning rods OUT. Injury can occur.
8. Cleaning Beneath Heat Exchanger
• Frequency: Monthly or after burning 1 ton of fuel
• By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off
. b. A more thorough cleaning is needed to remove the
excess ash that is left behind from the use of the
cleaning rods for the heat exchanger tubes.
c. The ash will be resting on the back of the baf es. This
will require removing the baf es. Please refer to page
37 for instructions on removing the baf es.
10. Cleaning the Glass
• Frequency: When clear view of the repot becomes
obscure.
• By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off.
b. Use a damp paper towel or any nonabrasive glass
cleaner. Wipe off with dry towel.
NOTE:
There are heavy duty vacuum cleaners speci cally
designed for solid fuel appliance cleaning.
9. Cleaning Exhaust Path
• Frequency: Yearly or more frequently depending on
ash build-up.
• By: Homeowner
a.
Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off
b. Open the hinged access door on the left of the
insert.
c. Reach in and unlatch the trap door that is connected
to the rear of exhaust blower.
d. Use a small vacuum hose attachment to clean area.
e. Re-latch and close trap door.
Handle glass assembly with care.
When cleaning glass:
Avoid striking, scratching or slamming
glass.
CAUTION
Do NOT clean glass when it is hot.
Do NOT use abrasive cleaners.
Use a hard water deposit glass cleaner on white lm.
Refer to maintenance instructions.
Service Parts
CB1200MI-MBK
Beginning Manufacturing Date: June 2009
Ending Manufacturing Date: Active
R
Classic Bay Millennium Insert - Pellet
4
5
6
7
8
9
10
11
17
19
18
20
21
22
3
2
1
11. Door Latch Inspection
• Frequency: Prior to heating season
• By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off
b. To adjust, open the latch and pivot the holding rod out.
Loosen the jam nut on the rod.
c. With a Phillips head screw driver, turn the rod clockwise
to tighten. The latch handle should snap securely in
place when adjusted properly.
d. After adjusting the latch, be sure to tighten the jam nut
on the rod to hold the adjustment.