User's Manual

©QTI Page 16 Revision: F
Form #: 30Z0138 Effective Date: 24 August 2006
EMIDS Transmitter (MMCT) Programming
Program 906: Fixed Mode Disabled
1. Set the switches to “000” – Press and release the test
button. The LED should turn to Amber. The unit is
now in the programming mode.
2. Set the switches to “906” – Press and release the test
button, the LED should turn to Green for two
seconds. The Fixed Mode is disabled.
Program 907: Power Down Mode Enabled
Warning: If the serial port is being used, this mode should be disabled to prevent the loss of communications
when the power down mode is activated.
The Power Down Mode puts the transmitter into a sleep mode five minutes after the transmitter is turned on. The
transmitter will revert to normal mode when triggered by a sensor. This mode will extend battery life, and should
be enabled when the unit is placed in the field.
1. Set the switches to “000” – Press and release the test
button. The LED should turn to Amber. The unit is
now in the programming mode.
2. Set the switches to “907” – Press and release the test
button, the LED should turn to Green for two
seconds. The Power Down Mode is enabled.
Program 908: Power Down Mode Disabled
Program 908 should be entered whenever the serial port is being used to program transmitters
1. Set the switches to “000” – Press and release the test
button. The LED should turn to Amber. The unit is
now in the programming mode.
2. Set the switches to “908” – Press and release the test
button, the LED should turn to Green for two
seconds. The Power Down Mode is disabled.
Amber
Amber
Amber
Turns
Green
for 2 Sec
Turns
Green
for 2 Sec
Turns
Green
for 2 Sec