User's Manual

©QTI Page 19 Revision: F
Form #: 30Z0138 Effective Date: 24 August 2006
EMIDS Transmitter (MMCT) Programming
Serial Port Baud Rates (cont.)
Baud Rate 2400 (932)
1. Set the switches to “000” – Press and release the test
button. The LED should turn to Amber. The unit is
now in the programming mode.
2. Set the switches to “932” – Press and release the test
button, the LED should turn to Green for two
seconds. Baud rate is set at 2400.
Baud Rate 1200 (933)
1. Set the switches to “000” – Press and release the test
button. The LED should turn to Amber. The unit is
now in the programming mode.
2. Set the switches to “933” – Press and release the test
button, the LED should turn to Green for two
seconds. Baud rate is set at 1200.
Serial Port Disabled (934)
1. Set the switches to “000” – Press and release the test
button. The LED should turn to Amber. The unit is
now in the programming mode.
2. Set the switches to “934” – Press and release the test
button, the LED should turn to Green for two
seconds. The serial port is turned off to conserve
battery life.
Program 999: Reset to Factory Defaults
1. Set the switches to “000” – Press and release the test
button. The LED should turn to Amber. The unit is
now in the programming mode.
2. Set the switches to “999” – Press and release the test
button, the LED should turn to Green for two
seconds. The transmitter is reset to the factory
defaults.
Amber
Turns
Green
for 2 Sec
Amber
Turns
Green
for 2 Sec
Amber
Turns
Green
for 2 Sec
Amber
Turns
Green
for 2 Sec