User's Manual

QTI Page 8 of 15 Revision: C
Form #: 30Z0266 Effective Date: 5 October 2012
Status Code Table
STATUS
CODE
ALARM TAMP/TEST LOBATT R>L L>R MEANING
00 0 0 0 0 0 RESERVED
01 0 0 0 0 1 RESERVED
02 0 0 0 1 0 RESERVED
03 0 0 0 1 1 FAULT
04 0 0 1 0 0 RESERVED
05 0 0 1 0 1 RESERVED
06 0 0 1 1 0 RESERVED
07 0 0 1 1 1 FAULT, LOBATT
08 0 1 0 0 0 TEST
09 0 1 0 0 1 RESERVED
0A 0 1 0 1 0 RESERVED
0B 0 1 0 1 1 TEST, FAULT
0C 0 1 1 0 0 TEST, LOBATT
0D 0 1 1 0 1 RESERVED
0E 0 1 1 1 0 RESERVED
0F 0 1 1 1 1 TEST, FAULT, LOBATT
10 1 0 0 0 0 ALARM
11 1 0 0 0 1 ALARM, L>R
12 1 0 0 1 0 ALARM, R>L
13 1 0 0 1 1 RESERVED
14 1 0 1 0 0 ALARM, LOBATT
15 1 0 1 0 1 ALARM, L>R, LOBATT
16 1 0 1 1 0 ALARM, R>L, LOBATT
17 1 0 1 1 1 RESERVED
18 1 1 0 0 0 TAMP
19 1 1 0 0 1 RESERVED
1A 1 1 0 1 0 RESERVED
1B 1 1 0 1 1 TAMP, FAULT
1C 1 1 1 0 0 TAMP, LOBATT
1D 1 1 1 0 1 RESERVED
1E 1 1 1 1 0 RESERVED
1F 1 1 1 1 1 TAMP, FAULT, LOBATT
ID CODE (III)
The unit ID code consists of three (3) decimal characters, but only EMIDS messages use all three.
MIDS, TRSS and REMBASS are limited to ID codes 000-063. EMIDS uses 000-999.
STATUS CODE (SS)
Status Codes depend upon the message format. MIDS has no status code, and these characters will
always be 00. EMIDS status codes are listed in the previous table.