User's Manual

RELEASED INTERNAL USE ONLY
RELEASED INTERNAL USE ONLY
Modifying your fixed phone antenna Remote Antenna Fixed Phone Rework Instructions
14 80-99438-1EN Rev. -
Ferrule
Crimp
312AA_01
Figure 25. Crimping the ferrule
16. Slip the shrink tubing up to the connector over the ferrule. Take the heat
device and heat the shrink tubing, turning the heat device around until
the shrink tubing shrinks.
Shrink tubing
313AA_01
Figure 26. Shrink tubing over ferrule
3.3 Installation cabling requirements
If you are using the bracket and quadrifilar helix antenna for your installation,
the following chart will provide you with the appropriate cable type based on
your installation length.
Table 3-1. Cable types for quadrifilar helix antenna
Cable Type Min Length (ft.) Cable Loss
Max Length
(ft.)
Cable Loss
LMR-100 8.5ft. 2.7 8.5ft 2.7
LMR-195 8.5ft. 1.2 19ft 2.7
LMR-240 8.5ft. 0.9 26ft 2.7
LMR-300 8.5ft. 0.7 33ft 2.7
LMR-400 8.5ft. 0.5 50ft 2.7
Note
In order to maintain proper regulatory performance limits, you
must keep the length of your cable within the above referenced
minimum and maximum lengths for the cable type used.