ELECTRIC FIREPLACE HEATER INSTRUCTION MANUAL M850P-36ACN NDF-65NB-1 ATTENTION: 1. Find a location for the fireplace heater that is protected from direct sunlight. 2. Do not plug the unit into the power outlet before you read all instructions.
SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS WHEN USING ELECTRICAL APPLIANCES, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO PERSONS, INCLUDING THE FOLLOWING: 1) Read all instructions before using this electric fireplace heater. IMPORTANT Please note when you open the carton carefully check the unit and make sure there are no damages.
SAFETY INSTRUCTIONS 8) Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Arrange cord away from traffic area and where it will not be tripped over. 16) Do not plug this product into a receptacle controlled by a wall switch or dimmer. 17) When storing or transporting the unit and cord, keep in a dry place, free from excessive vibration and store so as to avoid damage. 9) To disconnect fireplace, turn controls to off, then remove plug from outlet.
SAFETY INSTRUCTIONS heater. If the breaker trips when the heater is used then you may need to move the heater to another location or unplug other appliances that are on the same circuit. If you require an extension cord use one that is rated at 1875 watts. SAVE THESE INSTRUCTIONS FOR FUTURE USE.
A S S E M B LY I N S T R U C T I O N S PARTS LIST: A) Top panel 1 B) Base panel 1 C) Side panel 2 D) Left front panel 1 E) Upper front panel 1 F) Lower front panel 1 G) Right front panel 1 S) Connector 2 T) Short KD screws 3 U) Mounting clips 3 V) Mounting brackets 2 W) KD screws 60 X) Plastic connector 16 Y) SELF REPAIR SET Touch-up repair paint (bottle) L shape bracket 2 Screws for L shape 8 Plastic Connector 1 KD Screws 3 KD Nuts 3 TOOL REQUIRED: PHILLIPS HEAD SCREWDRIVER Z) WALL ANCHOR SAFETY CABLE Wa
A S S E M B LY I N S T R U C T I O N S Step 5: Place the LOWER FRONT PANEL [F] in between the lower section of 2 FRONT PANELS [D and G] and attach with 2 KD SCREWS (1 screw each side). See Fig. E. fig. B NOTE: If the KD SCREW(S) do not fit during assembly, loosen the 2 screws to adjust the PLASTIC CONNECTOR until the PANELS/KD SCREWS can be installed. fig. E Step 6: Carefully place the INSERT into the unit opening. The front of INSERT should be flush with the front of the mantel.
A S S E M B LY I N S T R U C T I O N S Step 10: Tighten all KD SCREWS. Step 11: Carefully move the assembled unit to the desired location. The Fireplace Mantel should not be positioned in an area exposed to direct sunlight. fig. G WALL ANCHOR SAFETY CABLE Step 8: Attach 3 MOUNTING CLIPS [U] onto the top of INSERT and lock in place with 3 SHORT KD SCREWS [T]. See Fig. H. The use of WALL ANCHOR SAFETY CABLE is highly recommended in order to reduce the risk of the fireplace being tipped over accidentally.
O P E R A T I O N fig. J After reading complete instructions, confirm all controls on fireplace are in the OFF position. Plug the fireplace into a 15AMP/120Volt outlet. If the cord does not reach, you may use an extension cord rated for a minimum of 1875 WATTS. Once the fireplace insert has been properly connected to a grounded electrical outlet, it is ready to operate. O/I: Press this button for main power and flame effect. The indicator light will turn on. See below for other control switches.
MAINTENANCE RISK OF FIRE: DO NOT EXCEED THE RECOMMENDED BULB WATTAGE. DIMMER CONTROL KNOB: Turn the dimmer dial clockwise or counter clockwise to get the desired flame intensity. The dimmer switch can only be used when the O/I switch is in the ON position. REPLACING THE LIGHT BULBS Step 1: Remove 4 screws on the back of fireplace and remove the rear cover of the unit. NOTE: When the ON/OFF switch is turned off, all other heater functions will stop even though the switches may be in the on position.
C L E A N I N G / W A R R A N T Y REPAIR SET Option 1: Use the spare KD NUTS, KD SCREWS and PLASTIC CONNECTOR 1. Place the PLASTIC CONNECTOR on the mantel unit and mark the drill-holes as shown in Fig. B. TOUCH UP REPAIR PAINT 1.Paint directly on the mantel unit if necessary. Fig. A. fig. B 2. Drill the holes with diameter 3/4 inches (10 mm) and depth 3/4 inches (10mm) on the mantel. Each Plastic Connector needs 3 holes. See Fig. C. fig.
C L E A N I N G / W A R R A N T Y 4. Attach the PLASTIC CONNECTOR and lock in place with KD SCREWS as shown in Fig. E. fig. G fig. H 3. Attach the SMALL L-BRACKET and lock in place with SCREWS as shown in Fig. H. OPTION 2: Use the SMALL L-BRACKETS and SCREWS. CLEANING 1. Place the SMALL L-BRACKET to the unit as shown and mark the drill-holes on the mantel as shown in Fig. F. To clean unit first turn off controls on unit and unplug the unit from power source.
W A R R A N T Y WARRANTY Every electric fireplace heater is tested before it leaves the factory and it is guaranteed for one year. If the unit should fail to operate correctly within one year from the date of purchase, call customer service at 1-800-459-4409 (EST). We will, at our discretion either repair or replace the unit. It will have to be returned to us freight prepaid and we will return the repaired or replaced unit to you freight prepaid.