ELECTRIC FIREPLACE HEATER INSTRUCTION MANUAL QCM650-38A-OAK NDF-65NB-3 ATTENTION: 1. Find a location for the fireplace heater that is protected from direct sunlight. 2. Do not plug the unit into the power outlet before you read all instructions.
SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS WHEN USING ELECTRICAL APPLIANCES, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO PERSONS, INCLUDI NG THE FOLLOWING: 8) Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Arrange cord away from traffic area and where it will not be tripped over. 1) Read all instructions before using this electric fireplace heater.
SAFETY INSTRUCTIONS 15) Avoid the use of an extension cord because the extension cord may overheat and cause a risk of fire. However, if you have to use an extension cord, the cord shall be No.14 AWG minimum size and rated not less than 1875 watts. The extension cord shall be a 3 wire cord with a grounding type cord and plug connector. 16) Do not plug this product into a receptacle controlled by a wall switch or dimmer.
SAFETY INSTRUCTIONS WARNING: IMPORTANT Procedures and techniques if not carefully followed - will result in damage to the equipment. - will expose the user to the risk of serious injury, illness or death. Please note when you open the carton carefully check the unit and make sure there are no damages. If you have any problems with the unit, with how the various functions work or with hidden damages or missing parts please call 1-800-459-4409 (EST) immediately for service.
A S S E M B LY I N S T R U C T I O N S PARTS LIST: A) Top panel B) Base panel C) Decorative bar D) Upper-front panel E) Lower-front panel F) Left front panel G) Right front panel H) Left small panel J) Right small panel K) Left side panel L) Right side panel M) Drop leaf N) Left Triangle support P) Right Triangle support Fireplace insert Q) KD screws R) Mounting clips S) Small screws T) Plastic connectors 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 60 3 6 16 U) WALL ANCHOR SAFETY C
A S S E M B LY I N S T R U C T I O N S Step 2: Attach the LEFT SMALL PANEL (H) to the LEFT FRONT PANEL(F) with 2 KD SCREWS. Attach the RIGHT SMALL PANEL (J) to the RIGHT FRONT PANEL(G) with 2 KD SCREWS. See fig. B fig. D Step 5: Place the LOWER FRONT PANEL (E) in between the lower sections of LEFT & RIGHT SMALL PANEL (H and J) and attach with 2 KD SCREWS (1 screw each side). See Fig. E fig. B Step 3: Attach the LEFT SIDE PANEL (K) to the LEFT FRONT PANEL (F) with 3 KD SCREWS.
A S S E M B LY I N S T R U C T I O N S Step 10: Install the TOP PANEL (A) to the unit as shown with 4 KD SCREWS. See Fig. J Step 7: Attach the DECORATIVE BAR (C) over the UPPER FRONT PANEL (D) and attach with 2 KD SCREWS (1 screws each side). See Fig. G fig. J fig. G Step 11: Tighten all SCREWS. Fig. K Step 8: Attach the LEFT TRIANGLE SUPPORT (N) on the LEFT SIDE PANEL (K). Attach the RIGHT TRIANGLE SUPPORT (P) on the RIGHT SIDE PANEL (L). See Fig. H fig. K FIREPLACE INSERT INSTALLATION: fig.
A S S E M B LY I N S T R U C T I O N S mantle opening. The front of the INSERT should be flush with the front of the mantle. and gently tap until the flange on the anchor is against the wall surface. Step 3: Once the INSERT is in place, attach 3 MOUNTING CLIPS (R) on the top of the INSERT and lock the insert in place with 3 SHORT KD SCREWS (X). See fig. L 2. Position the back edge of the mantle close to the wall. 3. Attach the SAFETY CABLE to the mantle using the SCREW FOR MANTLE. See figure M or N. 4.
O P E R A T I O N ON/OFF: Press this button for main power and flame effect. The indicator light will turn on. See below for other control switches. After reading complete instructions, confirm all controls on fireplace are in the OFF position. Plug the fireplace into a 15AMP/120Volt outlet. If the cord does not reach, you may use an extension cord rated for a minimum of 1875 WATTS. Once the fireplace insert has been properly connected to a grounded electrical outlet, it is ready to operate.
MAINTENANCE MAINTENANCE WARNING: REPLACING THE LIGHT BULBS Disconnect power and unplug the power cord before attempting any maintenance or cleaning to reduce the risk of fire, electric shock or damage to persons. The bulbs in your unit can become extremely hot. Allow at least 10 minutes between turning off the unit and removing the light bulbs to avoid the accidental burning of the skin. Step 1: Remove 4 screws on the back of fireplace and remove the rear cover of the unit.
R E PA I R S E T REPAIR SET Option 1: Use the spare KD NUTS, KD SCREWS and PLASTIC CONNECTOR 1. Place the PLASTIC CONNECTOR on the mantel unit and mark the drill-holes as shown in Fig. B. TOUCH UP REPAIR PAINT 1.Paint directly on the mantel unit if necessary. Fig. A fig. B 2. Drill the holes with diameter 3/4 inches (10 mm) and depth 3/4 inches (10mm) on the mantel. Each Plastic Connector needs 3 holes. See Fig. C. fig. A REPAIRS fig.
C L E A N I N G / W A R R A N T Y 3. Attach the SMALL L-BRACKET and lock in place with SCREWS as shown in Fig. H CLEANING fig. E Option 2: Use the SMALL L-BRACKETS and SCREWS 1. Place the SMALL L-BRACKET to the unit as shown and mark the drill-holes on the mantel as shown in Fig. F. To clean unit first turn off controls on unit and unplug the unit from power source.
W A R R A N T Y power source. Light bulbs are not covered by this warranty. The warranty is for homeowner use only and does not cover units used in commercial situations. Imported by Quality Craft Ltd. Laval, Quebec, Canada H7S 2G7 1-800-459-4409 (EST) www.qualitycraft.