User's Manual
Garage (Surface Mounted Installation):
Lay all sensors into the center of the spots as determined by your chalk lines
Go to Installifi > Zones > View Spots and run base_recalibration on all sensors in the zone.
Running a base_recal allows the sensors to start reporting magnetometer data
Go to each sensor page and check the Sensor History Series Data. Hover over the furthest-right
point to see the X, Y and Z magnetometer values
Check that all values are less than the absolute value of 1200 (less than 1200 or greater
than -1200)
If any values are outside of that threshold, move the sensor a couple inches to the left or
right in the spot, wait a couple minutes and check values again. Repeat until you find a
point near the center of the space that has good magnetometer readings (less than
absolute value 1200)
We prefer to move sensors left and right in the spot to keep the aeshetic so that if
someone looked down the line of sensors they'd all be in line
Put high viscosity (HV) adhesive on the bottom of the sensor and stick it in the spot
Default orientation is with the Parkifi 'P' facing up in the spot at 12 o'clock
If the antenna is in the direction of the top or bottom of the 'P', rotate the sensor 90
degrees so that the top of the 'P' is now at 3 o'clock
Put high viscosity (HV) adhesive around the outside of the ring. Put the ring down around the
sensor and stand on it