User Manual Part 1

Quanta Computer Inc. IEEE802.16e WiMAX IAD (WV202)
User Manual
211, Wen Hwa 2nd Rd., Kuei Shan Hsiang, CONFIDENTIAL
Tao Yuan Shien, Taiwan, R.O.C. Classification: proprietary information
http://www.quantatw.com
52
4.3 Server Setting
Field Description Default value
Authentication
Expired Time
SIP registration expired time. Assigns the time interval
from 60 – 65535, default setting is 3600 seconds.
3600
Authentication
Expired Time
Percentage
Before the expired time is timeout, IAD need to send a
re-register packet to SIP server for keeping the connection.
To set how many percentage of the expired time to send the
register packets.
50
Field Description Default value
(Line1 / Line2)
Domain Name Enter the SIP service domain name. In the full SIP URI,
this is the part after the @ symbol. You can use up to
127 printable ASCII Extended set characters.
Registrar Server
Address
Assigns the SIP Register Server’s IP address. 10.20.0.13 /
10.20.0.13
Registrar Server
Port
Port number of SIP Register Server. Assigns a value from
1 to 65535, default setting is 5060.
5060 / 5060
Proxy Address The IP address of a SIP proxy server receives requests
from clients and forwards them to another server.
10.20.0.13 /
10.20.0.13
Proxy Port Port number of SIP proxy Server. Assigns a value from 1 5060 / 5060