User guide

Table Of Contents
Safety
Information
Product
Information
Mechanical
Installation
Electrical
Installation
Getting
Started
Basic
parameters
Running the
Motor
Optimization
SMARTCARD
Operation
Onboard
PLC
Advanced
Parameters
Technical
Data
Diagnostics
UL
Information
34 Quantum MP User Guide
www.emersonct.com Issue: A3
Figure 4-4 Control connections for Quantum MP size 2 Drives
N/C
C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
C11
C12
C13
C14
C15
C16
E-Stop
Stop
Run
Jog
Fwd
Reset
Drive ON
Rev
Motor
Thermal
System
Interlocks
120 VAC
30 VA max.
C5
C6
C7
C8
Run
Two wire Run
Pr 6.40 = 0
Three wire Stop/Run
Pr 6.40 = 1
Programming Notes: Changes to Mentor MP USA Default Values
Parameter
Quantum MP Value
Description
5.16 1
DC Contactor
6.40 1
Enable sequencer latching
8.22 0.00
T25 digital I/O 2 source/ destination
8.23 0.00
T26 digital I/O 3 source/ destination
8.24 0.00
T27 digital input 4 destination
8.26 0.00
T29 digital input 6 destination
9.04 17.06
Logic function 1 source 1
9.05 1
Logic function 1 source 1 invert
9.09 0.1
Logic function 1 delay
9.10 10.32
Logic function 1 destination (External Trip)
9.37 1
Logic block 1 mode
17.21 6.39
SM-IO-120V T1 digital input 1 destination (Not stop)
17.22 6.34
SM-IO-120V T2 digital input 2 destination (Run)
17.23 6.31
SM-IO-120V T4 digital input 3 destination (Jog)
17.24 6.33
SM-IO-120V T5 digital input 4 destination (Forawrd/reverse)
17.25 10.33
SM-IO-120V T7 digital input 5 destination (Drive reset)
17.28 6.55
SM-IO-120V Relay 2 source (Contactor enable)
Control
Connections
From
X1 X2
T1
TB1